It was reported via literature entitled: primary and repeated stapled hemorrhoidopexy for prolapsing hemorrhoids: follow-up to five years.Authors: dennis raahave, m.D., d.M.Sci., lars v.Jepsen, m.D.And ib k.Pedersen, m.D.Citation: diseases of the colon and rectum; volume 51: 334¿341 (2008); doi: 10.1007/s10350-007-9102-6.This study was designed to assess initial results, analyze complications and failures, and document both the need for repeated procedures and the outcomes of follow-up to five years of stapled hemorrhoidopexy.Between june 8, 1999, and march 21, 2004, 258 patients (male=115, median age 55, range 29-83 years and female n=143, median age 52, range 23-87 years) with second-degree, third-degree, or fourth-degree hemorrhoids underwent modified stapled hemorrhoidopexy.After stretching the anorectal mucosa with forceps, a monocryl 2-0 pursestring suture was placed in the deep submucosa, approximately 3 cm above the dentate line, starting at the 8 o¿clock position and taking the suture anoscope in and out clockwise through the anoscope for every stitch.The staplers used were the eea in 12.7 percent (tycohealthcare, new haven, ct) and the hcs 33 and pph01 (ethicon endo-surgery, inc.) in 87.3 percent.After final closure, the stapling gun was fired and compressed for 2 minutes.Finally, a cylindrical hemostatic sponge (spongostan, ferrosan, copenhagen, denmark) was placed in relation to the staple line.Complications included persisting mucosal prolapse (n=31) in which subsequent surgical excisions were performed; bleeding less than 24 hours postoperative (n=15) in which hemostasis was done in 11 patients and conservative treatment was done in 4; bleeding less than 1 moth postoperative (n=6) in which hemostasis was done in 1 patient and conservative treatment was done in 5; stenosis (n=2) in which dilatation was performed; fissure (n=2) in which dilatation was done in one patient and conservative treatment was given to the other, fistula (n=1) and pain (n=5) which was treated with analgesics.Inspection after stapling revealed a lack of a staple line over some distance (partial stapling), resulting in a corresponding partial persistence of the mucosa prolapse (n=18).Thirteen patients had the prolapse excised, 2 were restapled immediately, and 3 were managed conservatively.One patient had to have a captured stapler head excised.In conclusion, the pain after stapled hemorrhoidopexy was low, recovery was rapid, complications were few, and patient satisfaction was high.A recurrent (or persistent) prolapse was alleviated by a repeated stapled hemorrhoidopexy for cure.However, there was a high risk of reintervention after a stapled hemorrhoidopexy, and this should be further evaluated.
|