• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MAKO SURGICAL CORP. PELVIC ARRAY ASSY; STEREOTAXIC DEVICE, ROBOTICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MAKO SURGICAL CORP. PELVIC ARRAY ASSY; STEREOTAXIC DEVICE, ROBOTICS Back to Search Results
Catalog Number 112230
Medical Device Problem Codes Detachment of Device or Device Component (2907); Premature Separation (4045)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 08/06/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
As part of normal complaint follow-up, an evaluation of the event has been initiated by mako surgical.A supplemental report will be submitted when additional information becomes available.
 
Event or Problem Description
During impaction the vizadisc kept popping off one of the pelvic array pegs that secures the vizadisc.It was determined after the case that the peg that secures the vizadisc was damaged after attempting to put another vizadisc on the array and not being able to keep it secure to the array.Case type: tha.
 
Additional Manufacturer Narrative
Reported event: during impaction the vizadisc kept popping off one of the pelvic array pegs that secures the vizadisc.It was determined after the case that the peg that secures the vizadisc was damaged after attempting to put another vizadisc on the array and not being able to keep it secure to the array.Case type: tha.Update: no debris/components left in patient.No components of the device missing or disassembled.Product evaluation and results: the reported device was confirmed to be a pelvic array assy, p/n 112230, lot 19170515.Functional test: all metal post are holding known good vizadisc, some wear was found on the posts.Product history review: review of the device history records indicate 50 devices were manufactured and accepted into final stock on 01-22-2016 with no reported discrepancies.Complaint history review: a review of complaints in catsweb and trackwise related to p/n 112230, lot number 19170515 shows zero additional complaint related to the failure in this investigation.Conclusions: the event could not be duplicated, as all metal post are holding known good vizadisc, some wear was found on the posts.Corrective action/preventive action: a review of stryker¿s nc/capa database indicated there have been no nc and capa associated with the product and failure mode reported in this event.
 
Event or Problem Description
During impaction the vizadisc kept popping off one of the pelvic array pegs that secures the vizadisc.It was determined after the case that the peg that secures the vizadisc was damaged after attempting to put another vizadisc on the array and not being able to keep it secure to the array.Case type: tha.Update: no debris/components left in patient.No components of the device missing or disassembled.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PELVIC ARRAY ASSY
Common Device Name
STEREOTAXIC DEVICE, ROBOTICS
Manufacturer (Section D)
MAKO SURGICAL CORP.
2555 davie road
fort lauderdale FL 33317
MDR Report Key8871208
Report Number3005985723-2019-00576
Device Sequence Number18964253
Product Code OLO
UDI-Device Identifier00848486002923
UDI-Public00848486002923
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K121064
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/27/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number112230
Device Lot Number19170515
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 08/06/2019
Supplement Date Received by Manufacturer10/30/2019
Initial Report FDA Received Date08/07/2019
Supplement Report FDA Received Date11/27/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
-
-