| Catalog Number |
656318 |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
07/18/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Upon completion of investigation, additional information will be provided in a supplemental report.
|
| |
|
Event or Problem Description
|
|
As reported: "variax screws locked into the plate and would not come out" and "needed to completely remove our product and put a different product in".
|
| |
|
Event or Problem Description
|
|
As reported: "variax screws locked into the plate and would not come out" and "needed to completely remove our product and put a different product in." additionally reported: "these each locked into the plate but were spinning as if they weren¿t locked.The heads did not strip but the surgeon was unable to back the screw out from the plate, and had to rip the entire construct out as one.This was the first case with this patient and was not a revision surgery.".
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event could not be confirmed, however the returned device was found to be damaged.Based on investigation, the root cause was attributed to be user related.The failure was caused by inadequate force during screw insertion.The device inspection revealed the following: the returned plate as well as most of the screws show severe damages / deformations.One screw is still positioned / stuck in the plate hole (spinning though).A close up of this screw shows that the locking thread is indeed badly damaged (unwound), which disables the screw from disengaging from the plate (stuck but still spinning).Similar deformations can be seen on the other screws as well, also most of the screw head interfaces are severely damaged / deformed which clearly indicates that high mechanical force was applied during screw insertion.Therefore the damages were caused during insertion as well as during removal.Note that the bone screw is still intact.Operative technique guide states: "note: when final tightening of the locking screw occurs, take care not to over-torque the screw.Excessive torque may damage the locking mechanism, the screw and/or the screwdriver blade (finger tighten only)." a review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.If any further information is provided, the investigation report will be updated.
|
| |
|
Search Alerts/Recalls
|