MEDTRONIC HEART VALVES DIVISION TRI-AD 2.0 ADAMS TRICUSPID ANNULOPLASTY RING; RING, ANNULOPLASTY Back to Search Results
Model Number 900SFC226
Medical Device Problem Codes Off-Label Use (1494); Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Information (3190)
Date of Event 04/09/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Other relevant device(s) are: product id: 9 00sfc226, serial/lot #: (b)(4), ubd: 12-sep-2023, udi#: (b)(4).Product analysis: no product was returned.Conclusion: without the return of the product, no definitive conclusion can be made regarding the clinical observation.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received information that this 25mm mitral annuloplasty band was implanted and explanted during the procedure for unknown reasons.It was replaced with a 25mm mitral mechanical valve.Three days later the patient also had a tricuspid bioprosthetic valve implanted and later that day passed away.No cause of death has been received at this time.
 
Additional Manufacturer Narrative
Corrected b5: medtronic received information that immediately following the implant of this tricuspid annuloplasty band implanted in the mitral position, it was explanted and replaced with a mitral mechanical valve.The reason for replacement was not reported.Section d: corrected the product that was reported and the associated product details.Serial number (sn) (b)(6) (tri-ad annuloplasty ring) was reported as a concomitant product on this initial regulatory report.The primary product on that report was model 500dm25 (open pivot mechanical valve), sn (b)(6).There is no complaint against the mechanical valve sn (b)(6).The reportable serious injury is against the tri-ad ring sn (b)(6).H6: corrected coding the patient death mentioned in this initial report was captured in death regulatory report # 2025587-2019-02601 medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRI-AD 2.0 ADAMS TRICUSPID ANNULOPLASTY RING
Common Device Name
RING, ANNULOPLASTY
Manufacturer (Section D)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
MDR Report Key8906136
Report Number3008592544-2019-00036
Device Sequence Number18868361
Product Code KRH
UDI-Device Identifier00643169335042
UDI-Public00643169335042
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
K093903
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Device Explanted Year2019
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/24/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date09/12/2023
Device Model Number900SFC226
Device Catalogue Number900SFC226
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 07/22/2019
Supplement Date Received by Manufacturer09/25/2019
Initial Report FDA Received Date08/19/2019
Supplement Report FDA Received Date10/24/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age55 YR
-
-