| Catalog Number |
1013470-080 |
| Medical Device Problem Code |
Defective Device (2588)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
07/30/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The customer reported the device was discarded.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.G9: exemption number e2019001-permits numbering sequence to begin with 10000, to avoid duplication of report numbers due to process transition.There may be gaps in numbering for reports submitted during the transition period.
|
| |
|
Event or Problem Description
|
|
It was reported that this was a percutaneous intervention, treating the proximal-mid superficial femoral artery (sfa).An unspecified 80mm stent was implanted.Following, the armada dilatation catheter advanced to the stent for post-dilatation.Once at the stent, the balloon was sticking out of the stent and the balloon was deemed longer than expected.The implanted stent was 80mm and the balloon length was also 80mm and the operator stated the balloon should not have been observed as longer than the stent.The balloon successfully post-dilated the stent without a device issue.There were no adverse patient effects and there was no clinically significant delay.No additional information was provided regarding this issue.
|
| |
|
Additional Manufacturer Narrative
|
|
Exemption number e2019001-permits numbering sequence to begin with 10000, to avoid duplication of report numbers due to process transition.There may be gaps in numbering for reports submitted during the transition period.The device was not returned for evaluation.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar incidents and/or complaints from this lot.Based on the information provided, a conclusive cause could not be determined.Per the armada 18 product specification, the workable balloon length measured from distal balloon shoulder to proximal balloon shoulder with balloon inflated to nominal pressure (np) for the 80 mm balloon has a tolerance of -5mm/+3mm.It may be possible that the balloon in question was at the higher end of the specification and therefore appeared oversized; however, this could not be confirmed.There is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.
|
| |
|
Search Alerts/Recalls
|