Model Number 4340
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Wound Dehiscence (1154)
Date of Event 08/27/2019
Type of Reportable Event Serious Injury
Event or Problem Description
The patient presented at the er with her chest wound opened up.She will follow up with an office visit to the implanting md.
 
Event or Problem Description
Patient was seen by implanting physician.The sense incision was open, but it was not infected.The skin edges are 2-3 mm apart for approximately 2/3 of wound.Mupirocin and steri-strips were applied.Oral antibiotic were prescribed.The issue was resolved as of (b)(6) 2019 and the patient was activated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INSPIRE MODEL 3028 IPG
Common Device Name
INSPIRE MODEL 4340 RESPIRATORY SENSING LEAD
Manufacturer (Section D)
INSPIRE MEDICAL SYSTEMS
5500 wayzata blvd.
suite 1600
golden valley MN 55416
MDR Report Key8946466
Report Number3007666314-2019-00069
Device Sequence Number16669051
Product Code MNQ
UDI-Device Identifier10855728005458
UDI-Public10855728005458
Combination Product (Y/N)Y
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
P130008
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/25/2020
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number4340
Device Catalogue Number900-009-001
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 08/27/2019
Supplement Date Received by Manufacturer01/14/2005
Initial Report FDA Received Date08/29/2019
Supplement Report FDA Received Date03/25/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Date Report Sent to FDA01/01/2005
-
-