• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON MEDICAL SYSTEMS NEEDLE SFTYGLD 22X1-1/2 RB; HYPODERMIC SINGLE LUMEN NEEDLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON MEDICAL SYSTEMS NEEDLE SFTYGLD 22X1-1/2 RB; HYPODERMIC SINGLE LUMEN NEEDLE Back to Search Results
Catalog Number 305900
Medical Device Problem Code Device Contamination with Chemical or Other Material (2944)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 08/19/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: unknown.The date received by manufacturer has been used for this field.Medical device expiration date: unknown.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device manufacture date: unknown.
 
Event or Problem Description
It was reported that 1 out of 20 total needles sftygld 22x1-1/2 rb was found with foreign matter in it before use, during a visual evaluation inspection.This complaint was created to capture the 9th of 9 related incidents.The following information was provided by the initial reporter: "305900 -ndl, 22g x 1.5 safety glide- 1 out of 20 found to have loose particulate." as part of our continuous improvement activities, the medical facility has undertaken an extensive visual evaluation of incoming components to characterize possible source of foreign material.The table below highlights the results of that inspection.Overall, 6.4 % had some type of loose particulate.(b)(6).
 
Additional Manufacturer Narrative
H.6.Investigation: since no samples displaying the condition reported are available for examination, we were unable to fully investigate this incident.No root cause can be determined as no samples were received.The lot number is unknown, therefore device history record review (dhr) or quality notification review (qn) could not be performed.H3 other text : see h.10.
 
Event or Problem Description
It was reported that (b)(4) out of (b)(4) total needles sftygld 22x1-1/2 rb was found with foreign matter in it before use, during a visual evaluation inspection.This complaint was created to capture the 9th of 9 related incidents.The following information was provided by the initial reporter: "305900 -ndl, 22g x 1.5 safety glide- (b)(4) out of (b)(4) found to have loose particulate." as part of our continuous improvement activities, the medical facility has undertaken an extensive visual evaluation of incoming components to characterize possible source of foreign material.The table below highlights the results of that inspection.Overall, 6.4 % had some type of loose particulate.Total loose: # inspected percentage: bd part # internal avid# description 682 10589 6.4% 304134 500604 syr, 10cc control l/l 6 52 11.5% 301073 500605 syr, 3cc l/l 43 1581 2.7% 301031 500608 syr, 20cc l/l 68 913 7.4% 301033 500609 syr, 30cc l/l 95 788 12.1% 301035 500611 syr, 60cc l/l 33 132 25.0% 301029 500620 syr, 10cc l/l 433 7016 6.2% 303005 500640 ndl, 18g x 1.5" rg bev 1 21 4.8% 381147 508408 angiocath 18g x 1.88" iv cath 2 66 3.0% 305900 509337 ndl, 22g x 1.5 safety glide 1 20 5.0%.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEEDLE SFTYGLD 22X1-1/2 RB
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
MDR Report Key8964673
Report Number1213809-2019-00890
Device Sequence Number19496684
Product Code FMI
UDI-Device Identifier30382903059004
UDI-Public30382903059004
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
K951254
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/10/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number305900
Device Lot NumberUNKNOWN
Initial Date Received by Manufacturer 08/19/2019
Supplement Date Received by Manufacturer08/19/2019
Initial Report FDA Received Date09/05/2019
Supplement Report FDA Received Date09/10/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-