| Model Number |
N/A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Loss of Range of Motion (2032)
|
| Date of Event |
05/20/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
On (b)(6) 2018, the patient underwent a right knee athroscopy, lysis of adhesions anterior notch adhesions manipulated under anesthesia, and a subchondroplasty.There were no intraoperative complications reported.On (b)(6) 2019, zimmer knee creations was notified that a patient had returned for treatment of decreased range of motion on (b)(6) 2019.The onset date was (b)(6) 2019, and the event was marked as resolved on (b)(6) 2019.It was noted that the subject did not gain any more motion over 20 degrees.The patient had previously reported that it was hard for them to stand due to their right knee.The product was not returned for the investigation, as it remains implanted in the patient.Once additional information becomes available about the event, a supplemental report will be submitted.
|
| |
|
Event or Problem Description
|
|
Clinical study subject (b)(6) experienced decreased range of motion after scp.
|
| |
|
Additional Manufacturer Narrative
|
|
The operative notes were received from the clinical procject lead and will be used as a part of the investigation.Once additional information becomes available, a supplemental report will be submitted.
|
| |
|
Event or Problem Description
|
|
Clinical study subject (b)(6) did not gain motion in knee.
|
| |
|
Additional Manufacturer Narrative
|
|
Scp knee randomized controlled trial subject (b)(6) underwent the initial subchondroplasty procedure on (b)(6) 2018 for a single bone marrow lesion in their right medial tibial plateau.3cc of accufill were injected.A lavage, debridement, and synovectomy a were also performed concomitantly.No intraoperative adverse events were reported.At a follow-up on (b)(6) 2019, the subject underwent a right knee arthroscopic lysis of anterior notch adhesions under anesthesia, as the subject did not gain any more motion over 20 degrees and a flexion contracture was determined.There were 161 days between the index and follow-up procedures.Per the health care professional assigned to this case, this event was probably related to the study surgical procedure (scp with arthroscopy) and possibly related to the accufill implant.The operative notes of the reoperation were provided for the investigation.The surgeon noted significant synovitis and scarring globally in the suprapatellar pouch, medial and lateral gutters, and just anterior to the notch.It was also noted that signification bony overgrowth over the acl, causing mechanical impingement in extension.The surgeon used a full radius shaver to reduce the bony overgrowth.The anterolateral notch had overgrowth with soft tissue, causing mechanical impingement of the acl.Again, the surgeon used a full radius shaver to remove the excess tissue.The acl and pcl were inspected and determined to be stable without injury.The decision was made to cast the patient in extension.The postoperative condition was noted as stable with minimal blood loss.The event was most likely caused by the patient anatomy and clinical conditions.A review of the finished goods dhr was conducted, and there were no nonconformances related to the complaint condition noted.The device in question remains implanted in the patient and therefore was not returned for the investigation.
|
| |
|
Event or Problem Description
|
|
Clinical study subject (b)(6) experienced decreased range of motion after scp.
|
| |
|