U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON INC. PDS+ U 45 CM M1.5 PS-4 MP; SUTURE, ABSORBABLE, SYNTHETIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON INC. PDS+ U 45 CM M1.5 PS-4 MP; SUTURE, ABSORBABLE, SYNTHETIC Back to Search Results
Catalog Number PDP509G
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).To date the device has not been returned.If the device or further details are received at the later date a supplemental medwatch will be sent.
 
Event or Problem Description
It was reported that the patient underwent an unknown orthopedic surgery on unknown date and the suture was used.During the surgery, the needle tip was broken during use though it was used in usual way.There were no adverse consequences to the patient reported.
 
Additional Manufacturer Narrative
(b)(4).Additional; it was reported performance needle breakage.A failed suture needle was submitted for fractographic evaluation.A fracture was observed at the tip of the needle.One side of the needle was received, the mating fracture surface was not provided for this evaluation.A microscope was used to examine the fracture surfaces and surrounding area of the needle.The fracture surfaces were examined in multiple locations in order to determine the fracture mode.The evaluation revealed the fracture was composed of microvoid coalescence, which is evidence of a ductile overload failure.This was a ductile fracture.The manufacturing records couldn't be reviewed as the batch number is unknown the evidence of this examination indicates that the breakage occurred at the tip of the needle during use due to tensile overload.There is no evidence of any material flaw or defect that would cause premature failure.In order to avoid this kind of damage grasp the needle in an area one-third (1/3) to one-half (1/2) of the distance from the attachment end to the point.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PDS+ U 45 CM M1.5 PS-4 MP
Common Device Name
SUTURE, ABSORBABLE, SYNTHETIC
Manufacturer (Section D)
ETHICON INC.
p.o. box 151, route 22 west
somerville NJ 08876 0151
MDR Report Key9086167
Report Number2210968-2019-87867
Device Sequence Number11337244
Product Code NEW
UDI-Device Identifier10705031207240
UDI-Public10705031207240
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K061037
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/21/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberPDP509G
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/09/2019
Initial Date Received by Manufacturer 08/21/2019
Supplement Date Received by Manufacturer10/09/2019
Initial Report FDA Received Date09/19/2019
Supplement Report FDA Received Date11/04/2019
Patient Sequence Number1
-
-