Model Number N/A
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: unknown.Occupation: lead tech.Pma/510(k) #: pre-amendment.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It was reported an unknown patient required placement of a ultrathane mac-loc locking loop biliary drainage catheter for a biliary drainage procedure.The operator reported the drainage catheter was leaking at the hub.The device was replaced with a similar device to complete the procedure.As reported, the patient did not experience any adverse effects or require any additional procedures due to this occurrence.
 
Additional Manufacturer Narrative
Blank fields on this form indicate the information is unchanged, unknown or unavailable.D10 ¿ product received on: 30sep2019.Investigation ¿ evaluation: a review of the complaint history, device history record, drawing, instructions for use (ifu), manufacturing instructions, quality control, and specifications of the device, as well as a visual inspection, functional test, and dimensional verification, were conducted during the investigation.The complaint device was returned for investigation.Physical examination of the returned device showed biomatter throughout the device, but no immediate surface damage was noted.A leak test was performed, and a leak was confirmed at the syringe-to-hub interface.Upon further inspection of the leakage site, a crack was noted on the luer lock portion of the mac-loc hub.All dimensions deemed relevant to the reported failure mode were analyzed and confirmed that the device was manufactured within specifications.Additionally, a document based investigation evaluation was performed.The proper procedures are in place to identify and prevent this failure mode prior to device distribution.The risk specifications covering mac-loc drainage catheters include both hub separation and leakage as a potential failure mode.The identified risk controls include manufacturing quality control checks and process validation.The technical files covering mac-loc drainage catheters indicate that the risks associated with these devices are acceptable when weighed against the benefits.The device history record (dhr) for the complaint lot and relevant subassemblies revealed no nonconformances relevant to the reported failure mode.A database search revealed no other complaints have been reported for the device lot.At this time, there is no evidence suggesting that nonconforming product from this lot exists in house or in the field.Based on the information provided, the examination of the returned product, and the results of the investigation, it was concluded that a component failure without manufacturing or design issue contributed to this incident.The appropriate personnel have been notified.Cook will continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRATHANE MAC-LOC LOCKING LOOP BILIARY DRAINAGE CATHETER
Common Device Name
GCA CATHETER, BILIARY, DIAGNOSTIC CATHETER, NEPHROSTOMY
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key9107003
Report Number1820334-2019-02392
Device Sequence Number16733831
Product Code GCA
UDI-Device Identifier00827002094994
UDI-Public(01)00827002094994(17)220618(10)9820235
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 12/11/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/18/2022
Device Model NumberN/A
Device Catalogue NumberULT12.0-38-40-P-32S-CLB-RH
Device Lot Number9820235
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/30/2019
Initial Date Received by Manufacturer 09/20/2019
Supplement Date Received by Manufacturer11/26/2019
Initial Report FDA Received Date09/23/2019
Supplement Report FDA Received Date12/11/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-