MENTOR TEXAS MENTOR MEMORYGEL BREAST IMPLANT; PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED
|
Back to Search Results |
|
| Catalog Number |
3545430 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Capsular Contracture (1761); No Code Available (3191)
|
| Date of Event |
03/01/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Since the device has not been returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors can be made.As such, the investigation will be closed.If the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.A manufacturing record evaluation (mre) was performed, and no anomalies were found related to this complaint.In addition, the mre verifies that the device was manufactured in accordance with documented specification and procedures.Reason for device explant and/or reoperation: generalized illness, capsular contracture.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a (b)(6)-year old caucasian female patient who underwent primary breast augmentation with two 430cc mentor memorygel breast implants, suffered several unexplained systemic symptoms, including weight gain and difficulty losing weight, dry eyes, very fatigued, cloudy eyes, vision burring very quickly, face is always puffy and swollen on the lower half, photosensitive (rash on face and arms), brain fog, lumps in right breast, calcification on the left breast, shortness of breath and tightness of chest.No device issue such as rupture was reported.The root cause of the patient¿s symptoms is unclear.As a result, the patient underwent bilateral removal on (b)(6) 2019.This medwatch form is for the right breast prosthesis.
|
| |
|
Additional Manufacturer Narrative
|
|
On 10/8/2019, the mentor failure analysis lab has received the device for evaluation.On 10/22/2019, the product investigation was completed.Device investigation summary: during evaluation of the sample it was observed to be intact.No anomalies were observed.Postoperative formation of a fibrous tissue capsule around a mammary prosthesis is a normal physiologic response to the implantation of a foreign object and occurs in all patients in varying degrees.In some cases, contracture of the fibrous capsule may occur.This phenomenon is referred to as capsular contracture.The manufacturing records were reviewed and the manufacturing criteria were met prior to the release of this lot.An investigation of the returned device was performed, and mentor could not uncover a device failure that we could connect to the reported medical symptoms.Manufacturer¿s reference number: (b)(4).
|
| |
|