PHILIPS ULTRASOUND, INC S8-3T MICRO TEE TRANSDUCER Back to Search Results
Model Number 989605431171
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Return of the suspect transducer is anticipated.Evaluation of the transducer will be included in a follow up report upon its return and investigation completion.
 
Event or Problem Description
A customer reported an s8-3t model transducer was not displaying images properly due to no articulation.There was no injury associated with this event.
 
Additional Manufacturer Narrative
Evaluation of the transducer confirmed the imaging and articulation issues as described by the customer.Investigation of the device noted debris in the window, cracked rubber on the handle, scratches on the control handle, and damage to the shaft.The physical damage to the transducer inhibited the overall performance of the device and is indicative of improper maintenance.Submission of a report does not constitute an admission that medical personnel, user facility, importer, distributor, manufacturer, or product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
S8-3T MICRO TEE TRANSDUCER
Common Device Name
S8-3T MICRO TEE TRANSDUCER
Manufacturer (Section D)
PHILIPS ULTRASOUND, INC
22100 bothell everett highway
bothell WA 98021
MDR Report Key9142038
Report Number3019216-2019-00067
Device Sequence Number14436945
Product Code ITX
UDI-Device Identifier00884838073524
UDI-Public(01)00884838073524
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K030455
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 09/25/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number989605431171
Device Lot NumberB2103K
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/18/2019
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 09/25/2019
Supplement Date Received by Manufacturer09/25/2019
Initial Report FDA Received Date10/01/2019
Supplement Report FDA Received Date01/21/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-