COOK INC ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER; GBO CATHETER, NEPHROSTOMY, GENERAL & PLASTIC SURGERY Back to Search Results
Model Number N/A
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 09/30/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Occupation: facilities lead.Pma/510(k) #: exempt.This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It was reported an unknown patient required placement of an ultrathane dawson-mueller mac-loc locking loop multipurpose drainage catheter for a paracentesis procedure.After placement, the device was reported to be leaking at the hub.It was replaced with a new similar device.No other adverse effects were reported for this incident.
 
Additional Manufacturer Narrative
Additional methods code: communication/interviews (4111).Concomitant medical product received on: 14oct2019.Investigation ¿ evaluation.A review of the complaint history, device history record, drawing, instructions for use (ifu), manufacturing instructions, quality control, and specifications of the device, as well as a visual inspection, functional test, and dimensional verification, were conducted during the investigation.The complainant returned one used and four unopened devices.On the surface of the used device there was biological matter but no damage.The distance between the hub and the cap was measured for the used device and it was determined to be out of specification.The tubing did not get pulled through the cap when tugged on, but did rotate within the cap when twisted.The device leaked at the end of the connector cap.Three of the unopened four devices leaked during testing.Further investigation of the unused devices will be included in medwatch report #1820334-2019-02792.Additionally, a document based investigation evaluation was performed.The proper procedures are in place to identify and prevent this failure mode prior to device distribution.The risk specifications covering mac-loc drainage catheters include both hub separation and leakage as a potential failure mode.The identified risk controls include manufacturing quality control checks and process validation.The technical files covering mac-loc drainage catheters indicate that the risks associated with these devices are acceptable when weighed against the benefits.The ifu supplied with the mac-loc drainage catheters instruct that the product should be inspected prior to use to ensure no damage has occurred.A review of the device history record (dhr) was also conducted as a part of the investigation.The dhr for the complaint lot and related subassembly lots revealed no reported nonconformances.A review of complaint software revealed six other complaints associated with this complaint lot.Three of these complaints are on the same failure mode and originated from the field.Based on this information, there is evidence that nonconforming product exists out in the field.Based on the information provided, inspection of the returned product and the results of the investigation, cook has concluded that a manufacturing and quality control deficiency contributed to this incident.Corrective actions including implementation of a gap gauge and retraining were performed.Appropriate measures have been taken to address this failure mode.The appropriate personnel have been notified.Per the quality engineering risk assessment no further action is required.Cook will continue to monitor for similar complaints.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER
Common Device Name
GBO CATHETER, NEPHROSTOMY, GENERAL & PLASTIC SURGERY
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key9167041
Report Number1820334-2019-02551
Device Sequence Number2164927
Product Code GBO
UDI-Device Identifier00827002515949
UDI-Public(01)00827002515949(17)220610(10)9799196
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/16/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/10/2022
Device Model NumberN/A
Device Catalogue NumberULT6.3-35-15-P-5S-CLDM-HC
Device Lot Number9799196
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/14/2019
Initial Date Received by Manufacturer 09/30/2019
Supplement Date Received by Manufacturer01/16/2020
Initial Report FDA Received Date10/08/2019
Supplement Report FDA Received Date01/16/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No