Model Number 7134
Medical Device Problem Code Break (1069)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Date of Event 09/01/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: used the first day of the month of the aware date as there was no date provided.
 
Event or Problem Description
It was reported that shaft break occurred.A 3.00mm x 20mm emerge balloon catheter was selected for use.However, the balloon broke and had to be retrieved.No patient complications were reported.
 
Additional Manufacturer Narrative
Date of event: used the first day of the month of the aware date as there was no date provided.Device evaluated by mfr.: returned product consisted of an emerge balloon catheter.The shaft, hypotube, tip and balloon were microscopically and visually examined.There were numerous kinks.There was a complete separation at 23.6cm distal of the strain relief.There was contrast in the inflation lumen and balloon, and blood in the guidewire lumen.The balloon was loosely folded.Inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
It was reported that shaft break occurred.A 3.00mm x 20mm emerge balloon catheter was selected fo use.However, the balloon broke and had to be retrieved.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EMERGE
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key9206004
Report Number2134265-2019-12321
Device Sequence Number305155
Product Code LOX
UDI-Device Identifier08714729806349
UDI-Public08714729806349
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K113220
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/04/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number7134
Device Catalogue Number7134
Device Lot Number0024225982
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/22/2019
Initial Date Received by Manufacturer 09/27/2019
Supplement Date Received by Manufacturer11/14/2019
Initial Report FDA Received Date10/17/2019
Supplement Report FDA Received Date12/04/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-