| Model Number |
03.311.001 |
| Medical Device Problem Code |
Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
09/27/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Patient ref.# (b)(6).The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2019, during a foot surgery, the two (2) tensioners would not release reduction wire during the application of a distraction osteogenesis (do) ring fixator frame.It came apart during the attempts to release the wire from the tensioner intraoperatively.There are two tensioners that failed during the procedure.Another one (1) tensioner comes to a hard stop when completely releasing tension.It is supposed to click and continue to rotate when all tension has been released reaching its endpoint however, it did not ¿click¿ when the handle was fully opened.The same type of tensioner was used to complete the procedure.No issue with wire.Tensioner¿s failed on both reduction wires and smooth wires.Right lower extremity multiplanar ring external fixator.Wire did not appear to be the issue.Tensioner malfunction occurred on several different wires.Two of the tensioners terminally impinged on the wire.In an effort to release the tensioner from the wire the physician continued to turn the handle counter clockwise.Two of the tensioners became disassembled.There was no surgical delay.The procedure successfully completed.No patient consequence.Concomitant device reported: unknown ring fixator frame (part# unknown, lot# unknown, quantity 1).This report is for 3 of 5 for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.A review of the device history record.Device history lot.Part #: 03.311.001.Supplier lot #: 1672660.Manufacturing site: hägendorf.Release to warehouse date: 27 april 2007.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.The returned tensioner was forwarded to the manufacturing side for evaluation.The statement below is a summary of their investigation.Shipped back device ¿tensioner¿ 03.311.001 with lot number 1672660 is in used conditions.Scratches are present all over the device and signs of a heavy use are present in particular on the reaction fork, top and lower parts and on the central shaft.It looks like it has been hit with huge strength.Anyway, the device looks like able to function.After having reviewed inspection sheet se_026728, version aa valid when the device was manufactured (24.04.2007), and the more recent version ag, functional tests were performed on the 03.311.001 tensioner with lot number 1672660 in order to investigate the complaint.The following functional tests were performed: the device passed all the functional tests performed.The complaint could not be replicated with the returned device and no functional issue can be confirmed.The following documents were reviewed: device history record (dhr) 6647776; inspection sheet se_026728 version aa, ¿prüfanweisung/ prüfnachweis¿; a dhr review was already performed as part of the overall product investigation by customer quality and it is documented in the product investigation pi-15718496149586328.Part #: 03.311.001.Supplier lot #: 1672660.Manufacturing site: hägendorf.Release to warehouse date: 27 april 2007.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.However, in order to perform the investigation, all the documents mentioned above, valid when the device was manufactured, have been analyzed.The manufacturing process was executed according to the analyzed documents.Evidences confirm that no functional issues are present.For this reason, the complaint is not confirmed and since no manufacturing related issue was identified and/or confirmed, review to the specific prm and prm line is not applicable.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed as no product related issue could be detected.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10: additional narrative: device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|