BIOMET MICROFIXATION TMJ SYSTEM LEFT STANDARD MANDIBULAR COMPONENT; JOINT, TEMPOROMANDIBULAR, IMPLANT
|
Back to Search Results |
|
| Model Number |
N/A |
| Medical Device Problem Codes |
Device Dislodged or Dislocated (2923); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); No Code Available (3191)
|
| Date of Event |
09/12/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Zimmer biomet complaint (b)(4).The investigation is in process.It is unknown at this time if the device will be returned for evaluation.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001032347-2019-00470, 0001032347-2019-00472, 0001032347-2019-00473, 0001032347-2019-00474, 0001032347-2019-00475, 0001032347-2019-00476.Medical products: tmj system left standard mandibular component, part# 24-6551, lot# 516390a, tmj system left standard mandibular component, part# 24-6556, lot# 509470b, tmj system left fossa component small, part# 24-6563, lot# 523730a, 2.4mm system high torque (ht) cross-drive screw, part# 91-2710, lot# unknown, 2.4mm system high torque (ht) cross-drive screw, part# 91-2712, lot# unknown, tmj system cross drive fossa screw, part# 99-6577, lot# unknown, tmj system cross drive fossa screw, part# 99-6579, lot# unknown.
|
| |
|
Event or Problem Description
|
|
It was reported the patient underwent a revision to remove temporomandibular implants due to an unknown reason.Attempts have been made to gather more information but none has been provided.No additional patient consequences have been reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.As a revision surgery was reported, the complaint is confirmed.No product was returned; therefore, no functional tests or inspections could be performed.No x-rays, scans, pictures, or physician's reports were provided.The dhrs for the mandible component was reviewed.Nc5773 was opened to document the rework of one 24-6556 from this lot that was found to have scuff marks.The reworked component passed quality inspection.There are no indications of manufacturing defects.For all non-custom tmj mandibular implants in the previous one year (from the notification date) regarding pain leading to a revision surgery, there is a complaint rate of (b)(4), which is no greater than the occurrence listed in the afmea.This is the only complaint regarding pain and dislocation leading to a revision surgery for part# 24-6556 lot# 509470b.The most likely underlying cause of the complaint could not be determined.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.The following fields were updated: date of this report, describe event or problem, device availability, date received by manufacturer, type of report, follow up type, device evaluated by manufacturer, method code, results code, conclusions code, additional narratives/data.
|
| |
|
Event or Problem Description
|
|
This follow-up report is being submitted to relay additional information.It was reported the patient complained of pain and open lock jaw approximately four months prior to the revision surgery.A surgical exploration and joint replacement was performed, and the surgeon noted there were no visible defects to the hardware, just a lot of scar tissue.
|
| |
|