Catalog Number 30600080S
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Codes Injury (2348); No Code Available (3191)
Date of Event 10/08/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device will not be returned.If additional information becomes available, it will be provided in a supplemental report.Hospital retained.
 
Event or Problem Description
It was reported that the patient's right femur was revised due to failed fixation of the short gamma nail.Patient was revised to a stryker hemi hip construct.Rep reported that he can provide an x-ray and confirmed that no further information is available.
 
Additional Manufacturer Narrative
The reported event could not be confirmed, since the device was not returned for evaluation and only an x-ray was shared by the customer.With the available medical information and the x-ray provided, a medical opinion was sought from the medical expert, but no conclusive statement or opinion could be made due to insufficient information.More detailed information about the complaint event as well as the affected device, pre-operative x-ray, post-operative x-ray and patient¿s medical records must be available in order to determine the root cause of the complaint event.The probable root cause of the complaint event could be due to poor positioning of the lag screw and the patient factor.The provided lot number is incorrect; therefore a review of the device history could not be performed.No corrective actions are required at this time.No indications of manufacturing or design related problems were found during the investigation.A review of the labeling did not indicate any abnormalities.If the device is returned or if any additional information is provided, the investigation will be reassessed.
 
Event or Problem Description
It was reported that the patient's right femur was revised due to failed fixation of the short gamma nail.Patient was revised to a stryker hemi hip construct.Rep reported that he can provide an x-ray and confirmed that no further information is available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LAG SCREW, TI GAMMA3® Ø10.5X80MM
Common Device Name
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
MDR Report Key9258555
Report Number0009610622-2019-00906
Device Sequence Number11384288
Product Code HSB
UDI-Device Identifier04546540374905
UDI-Public04546540374905
Combination Product (Y/N)N
Initial Reporter StateRI
Initial Reporter CountryUS
PMA/510(K) Number
K032244
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Device Explanted Year2019
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/03/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Catalogue Number30600080S
Device Lot NumberK0A3013D
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 10/08/2019
Supplement Date Received by Manufacturer12/09/2019
Initial Report FDA Received Date10/30/2019
Supplement Report FDA Received Date01/03/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Weight54
-
-