Model Number U228
Device Problems Over-Sensing (1438); Low impedance (2285); Connection Problem (2900); Device Sensing Problem (2917); High Capture Threshold (3266)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 09/04/2019
Event Type  malfunction  
Manufacturer Narrative
As no further information regarding this event is expected, our investigation is complete.This report will be updated should additional information be provided.
 
Event Description
It was reported that this newly implanted cardiac resynchronization therapy pacemaker (crt-p) exhibited oversensing of noise on the right ventricular (rv) channel.The physician suspected the set screw connecting the rv lead may have not been properly secured.A polarity switch was also observed with the system due to a low out of range pacing impedance measurement of less than 200 ohms on the rv channel.In unipolar mode, no noise was observed however the rv thresholds were slightly high.The physician decreased the sesitivity of the system and the crt-p remains implanted and in service.No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VISIONIST X4 CRT-P
Type of Device
PULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key9270202
MDR Text Key168817621
Report Number2124215-2019-23396
Device Sequence Number1
Product Code NKE
UDI-Device Identifier00802526559471
UDI-Public00802526559471
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
P030005/S138
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 11/02/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date01/25/2021
Device Model NumberU228
Device Catalogue NumberU228
Device Lot Number739419
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/04/2019
Initial Date FDA Received11/02/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/20/2019
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
-
-