Catalog Number 14324
Medical Device Problem Code Appropriate Device Problem Term/Code Not Available (3191)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 04/26/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Initial reporter phone #: (b)(6).(b)(4).Test specifications for product release were met.No issues were observed in the dhr that would contribute to the complaint.Asp complaint ref #: (b)(4).
 
Event or Problem Description
A customer reported a positive result with a cyclesure® 24 biological indicator (bi) after a completed sterrad® cycle.The affected load was released and used on a patient.There was no report of infection, injury or harm to patient(s) associated with this issue.Although there is no report of patient injury or harm and no prior incidents have resulted in serious injury, advanced sterilization products (asp) has determined in this situation sterility cannot be assured.Therefore, as a matter of policy asp had decided to report all incidents of positive cyclesure® 24 biological indicators when the load has been released and used on patient(s) prior to reprocessing.
 
Additional Manufacturer Narrative
It was initially reported that the load was released and used on a patient; however, the affiliate later confirmed that the load was recalled/reprocessed.H3: asp investigation summary: the investigation included a review of the device history record (dhr), trending of lot number, system risk analysis (sra), visual analysis and retains analysis.Trending analysis by lot number was reviewed from 11/09/2018 to 04/27/2019 and trending was not exceeded.The sra indicates the risk associated with a quality problem with no impact on safety is "low." the single cyclesure® 24 bi was not available for return and visual analysis.Thirty-two retains bis were subject to functional evaluation.All thirty-two bis met specification.The suspect positive bi issue could not be confirmed as the suspect product was not available for return and visual analysis.There is no evidence to suggest an alleged deficiency since the dhr review found no anomalies that would contribute to a positive bi result, retains product met functional specifications and lot history review did not show any significant trend.The issue will continue to be tracked and trended.Asp complaint ref #: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CYCLESURE® BIO INDICATOR
Common Device Name
INDICATOR, BIOLOGICAL
Manufacturer (Section D)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
MDR Report Key9276071
Report Number2084725-2019-00981
Device Sequence Number18864344
Product Code FRC
UDI-Device Identifier10705037016211
UDI-Public10705037016211
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K994055
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/11/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/31/2019
Device Catalogue Number14324
Device Lot Number31318099
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 10/11/2019
Supplement Date Received by Manufacturer11/06/2019
Initial Report FDA Received Date11/04/2019
Supplement Report FDA Received Date11/15/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No