| Model Number |
MY8030 |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Patient Involvement (2645)
|
| Date of Event |
10/08/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Concomitant medical products: tecentriq 1200mg/20ml, genentech ndc 50242-917-01, lot 3319781, exp 3/22.Although requested, the affected product has not been received.A follow up report will be submitted with investigation results should the devices be received for evaluation.
|
| |
|
Event or Problem Description
|
|
It was reported that a texium syringe had major employee safety and patient safety concerns.Tecentriq residue found on the smartsite of the 20mm vialshield after drawing up drug and disconnecting the texium bonded syringe from vialshield.Tecentriq residue found on the smartsite bag access of the texium infusion set after injecting tecentriq into the smartsite bag access with the texium bonded syringe.This event occurred in the pharmacy and there was no patient involvement.
|
| |
|
Event or Problem Description
|
|
It was reported that a texium syringe had major employee safety and patient safety concerns.Tecentriq residue was found on the smartsite of the 20mm vialshield after drawing up drug, and disconnecting the texium bonded syringe from the vialshield.Tecentriq residue was found on the smartsite bag access of the texium infusion set after injecting tecentriq into the smartsite bag access with the texium bonded syringe.This event occurred in the pharmacy and there was no patient involvement.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction to section d.4, (lot number).Additional information provided section d.10.************************************************** the customer¿s report that residue was found on the smartsite of the 20mm vialshield after drawing up drug and disconnecting the texium bonded syringe was confirmed after review of the picture evidence the customer provided.The vialshield and texium syringe were visually inspected for cracks, holes/tears or damages to the components.Visual inspection observed no residue with the received texium or smartsite vialshield.Functional testing did not find any leaks or replicate any instances of residue when activating and deactivating the mating components between the texium syringe and smartsite vialshield.The root cause of the customer¿s report could not be determined because no leftover residue was replicated during internal lab testing.
|
| |
|
Search Alerts/Recalls
|