| Catalog Number |
5954610 |
| Medical Device Problem Codes |
Defective Device (2588); Patient-Device Incompatibility (2682); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Hernia (2240); Injury (2348)
|
| Date of Event |
03/03/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made regarding the bard/davol ventralight st (device #1) used to treat the patient.The patient's attorney did allege surgical intervention; however, no details have been provided.No lot number has been provided therefore a review of the manufacturing records is not possible.This emdr represents the bard/davol ventralight st (device #1).An additional emdr was submitted to represent the bard/davol ventrio st (device #2).Should additional information be provided a supplemental emdr will be submitted.Not returned.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st (device #1) or an unspecified bard/davol ventrio st (device #2) on (b)(6) 2014 or (b)(6) 2017.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device(s).As reported, the patient is making a claim for an adverse patient outcome against the bard/davol ventralight st (device #1) and the ventrio st (device #2).As reported, the attorney alleges patient experienced emotional distress and the device was defective.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st (device #1) or an unspecified bard/davol ventrio st (device #2) on (b)(6) 2014 or (b)(6) 2017.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device(s).As reported, the patient is making a claim for an adverse patient outcome against the bard/davol ventralight st (device #1) and the ventrio st (device #2).As reported, the attorney alleges patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2014 - patient was diagnosed with incarcerated infraumbilical and periumbilical incisional hernia thereby underwent laparoscopic repair with implant of ventralight st (device 1).Per op notes, ¿a large incarcerated incisional hernia at the level of umbilicus.The hernia was reduced.The incarcerated omentum was reduced.A ventralight st (device 1) was placed and tacked.¿ (b)(6) 2017 - patient was diagnosed with recurrent incisional ventral hernia thereby underwent laparoscopic converted to open repair with excision of ventralight st (device 1) and implant of ventralight st (device 2), ventrio st (device 3).Per op notes, ¿the hernia sac was identified and adherent to abdominal wall.The contents of hernia sac were reduced.The failed prior mesh (device 1) was resected.The hernia sac also excised.A ventralight st (device 2) was placed and intra-abdominal cavity and secured with sutures.The ventrio st (device 3) was placed and tacked.¿ (b)(6) 2017 - patient was diagnosed with fascial dehiscence with small bowel evisceration thereby underwent open repair with excision of ventralight st (device 2), ventrio st (device 3) and implant of phasix mesh (device 4), xenmatrix ab (device 5).Per op notes, ¿the previously placed meshes (device 2 and 3) were removed.The prior tacks were removed.A xenmatrix (device 5) was placed in the intra-abdominal cavity and secured with tacks.Phasix mesh (device 4) was placed as onlay and secured using sutures.¿ (b)(6) 2019 - patient was diagnosed with recurrent ventral hernia thereby underwent open repair with excision of phasix mesh (device 4) and implant of biological mesh.Per op notes, ¿the hernia sac was identified and excised.Adhesions were lysed.The prior mesh (device 4) was excised.A biological mesh was placed and sutured.¿.
|
| |
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made regarding the bard/davol ventralight st (device #1) used to treat the patient.The patient's attorney did allege surgical intervention; however, no details have been provided.No lot number has been provided therefore a review of the manufacturing records is not possible.Addendum: this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-jun-2012) is considered to be a best estimate.This supplemental emdr represents the bard/davol ventralight st (device #1).An additional supplemental emdr and two emdrs were submitted to represent the bard/davol ventrio st (device #3), ventralight st (device #2) and phasix flat mesh (device #4).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|