MAUDE Adverse Event Report: RAYNHAM PROG VALVE INLINE W SG; CHPV WITH SG

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

RAYNHAM PROG VALVE INLINE W SG; CHPV WITH SG Back to Search Results
Catalog Number 823832
Device Problem Blocked Connection (2888)
Patient Problem No Information (3190)
Event Date 10/03/2019
Event Type  malfunction  
Manufacturer Narrative
Attempts are being made to obtain additional information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
It was reported that the valve was implanted to the patient via vp-shunt.The initial setting was unknown.However, the patient had a ventricular enlargement and occlusion was observed by shunt contrast.Therefore it was replaced with a new valve.The patient is recovering now.
 
Event Description
N/a.
 
Manufacturer Narrative
Review of the history device records for the valve, product code 82-3832 with lot 3426957, conformed to the specifications when released to stock.Failure analysis: the valve was visually inspected: no defects noted.The valve passed the tests for programming, occlusions, leaks, reflux and pressure.No root cause could be determined, as the technician was unable to confirm the problem reported by the customer at the time of the investigation the valve functions between 05nov2019 and 30jun2020, approximately 2,200 mdrs submitted electronically by integra lifesciences via trackwise, integra's complaint handling system, were not received by cdrh due to a computer system issue.Within this time period, an error with integra's middleware, which facilitates communications between trackwise and the fda system, caused the complaint records to close and indicate we had received an acknowledgement 3 from the fda when we had not.Integra interpreted the acknowledgement as a successful submission; however, subsequent investigation revealed the acknowledgement 3 received was from our middleware and not from the fda (these acknowledgements have been retained as part of the documentation of the mdr).The malfunction was related to the relocation of the trackwise application to a new data center during the transition of integra's corporate headquarters from plainsboro, nj to princeton, nj.Previously, integra had been successfully receiving acknowledgements 1, 2, and 3 from the fda, and our records reflect these acknowledgements, including the date and time stamps.Capa pr 229048 and nc 20-011 have been opened by integra to further investigate the nonconformance and develop a corrective action plan.The middleware error has been corrected, and integra has filed mdrs since the correction and verified that the appropriate acknowledgements have been received from the fda.Integra is resubmitting all impacted mdr reports for the time period 05nov2019 through 30jun2020.Integra lifesciences contacted (b)(6) , director of regulatory programs, office of product evaluation and quality and (b)(6) , assistant director, mdr team, office of product evaluation and quality on july 8-9, 2020 to report these issues regarding mdr reports.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROG VALVE INLINE W SG
Type of Device
CHPV WITH SG
Manufacturer (Section D)
RAYNHAM
325 paramount drive
325 paramount drive
raynham MA 02767
MDR Report Key9376875
MDR Text Key191858222
Report Number1226348-2019-00535
Device Sequence Number1
Product Code JXG
Combination Product (y/n)N
PMA/PMN Number
K053107
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 11/01/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/26/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number823832
Device Lot Number3426957
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/03/2019
Date Manufacturer Received02/07/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-