Catalog Number SNGHK2
Health Effect - Clinical Code Unspecified Infection (1930)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Date of event: publication year of 2014.Medical device: batch # unk.This report is related to a journal article; therefore, no product will be returned for analysis and the manufacturing records cannot be reviewed as the lot/batch number has not been provided.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Does the author/surgeon believe that the ethicon device caused or contributed to the patient complications mentioned in the article? if yes, please explain.
 
Event or Problem Description
Title: quicker yet safe: skeletonization of 1640 internal mammary arteries with harmonic technology in 965 patients.Author: teresa m.Kieser, m.Sarah rose, uthman aluthman and kishan narine.Citation: european journal of cardio-thoracic surgery 45 (2014) e142¿e150 / doi:10.1093/ejcts/ezu024.The purpose of this retrospective analysis of prospectively collected data was to compare major adverse cardiac events (maces) related to ima grafting between non-harmonic scalpel (hs) and hs patients, and compare times of harvest between non-hs harvest and hs harvest.From july 2003 to july 2013, a total of 1051 patients with isolated coronary artery bypass graft (cabg) were included in the study.Ima conduits were harvested in a skeletonized manner either with the traditional skeletonization technique (with use of the cautery tip without power as a dissector) (n=86, n=22 female, mean age 67.7 years) or with an ultrasonic scalpel (harmonic scalpel; ethicon endo-surgery) (n=965, n=206 female, mean age 64.7 years).In harmonic scalpel group, the harmonic scalpel was used to isolate and free the ima, from its distal bifurcation into the superior epigastric and musculophrenic branches to proximally above the first intercostal branch.In the harmonic technique, branches were sealed using the blunt end of the harmonic device.Postoperative complication included deep sternal wound infection (n=15).In this largest series to date of harmonic ima skeletonization, this technique results in rare damage, is quicker and with a comparable adverse event rate compared with the non-harmonic method.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HS SYNERGY COMBO HOOK BLADE
Common Device Name
INSTRUMENT, ULTRASONIC SURGICAL
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
MDR Report Key9386033
Report Number3005075853-2019-23815
Device Sequence Number2403277
Product Code LFL
UDI-Device Identifier10705036013815
UDI-Public10705036013815
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
SNGHK2
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,literature
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 10/31/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberSNGHK2
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/31/2019
Initial Report FDA Received Date11/27/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-