ALCON RESEARCH, LLC - HOUSTON CENTURION SURGICAL PROCEDURE PAK; GENERAL SURGERY TRAY (KIT) Back to Search Results
Catalog Number ASKU
Device Problem Break (1069)
Patient Problems Fluid Discharge (2686); Device Embedded In Tissue or Plaque (3165)
Event Date 11/05/2019
Event Type  Injury  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Event Description
A company representative reported a surgeon experienced a broken phaco needle during a procedure.Upon completion of the procedure, it appeared as "nothing was wrong".The patient returned for the one day postoperative visit and was experiencing a wound leakage.The surgeon took the patient back to the operating room to place a suture in the wound and during this procedure, he found a small, clear piece of material in the wound.During the sixth day postoperative visit after the second procedure, the surgeon indicated the patient is doing well, the eye was quiet and the wound was secure.
 
Manufacturer Narrative
A sample was not received at the manufacturing site for evaluation for the report of phaco needle broke off in eye, wound leak and foreign material retained; therefore, the condition of the product could not be verified.No lot number was identified with this complaint; therefore, lot record reviews could not be conducted.A sample was not received at the manufacturing site and no lot information was provided; therefore, the root cause for the customer complaint issue cannot be determined.The exact root cause for this complaint is unknown; therefore, specific action with regards to this complaint cannot be taken.All phaco tips are 100% visually inspected by trained operators using 30x magnification during the manufacturing process.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTURION SURGICAL PROCEDURE PAK
Type of Device
GENERAL SURGERY TRAY (KIT)
Manufacturer (Section D)
ALCON RESEARCH, LLC - HOUSTON
9965 buffalo speedway
houston TX 77054
MDR Report Key9387156
MDR Text Key168434073
Report Number1644019-2019-00184
Device Sequence Number1
Product Code LRO
Combination Product (y/n)N
PMA/PMN Number
K880961
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 02/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/27/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberASKU
Device Lot NumberASKU
Was Device Available for Evaluation? No
Date Manufacturer Received01/30/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-