Model Number 3092-020
Medical Device Problem Code Loss of or Failure to Bond (1068)
Health Effect - Clinical Codes Edema (1820); Pain (1994); Discomfort (2330); No Code Available (3191)
Date of Event 02/26/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Occupation is a non-healthcare professional.(b)(4).
 
Event or Problem Description
The patient underwent a left knee revision due to loosening of the tibial component, swelling, mild flexion instability, and pain.The surgeon indicated the tibial component was completely de-bonded at the cement/implant interface, and well-fixed to the proximal tibia.He did not speak to the state of the femoral component though it was revised.The surgeon indicated the patellar component was tracking central and was revised.The patient was implanted with attune knee system and smartset bone cement x 2.There were no complications reported with the procedure.Doi: (b)(6) 2015; dor: (b)(6) 2019; (lt knee).
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.Depuy synthes considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.Device history lot : 0 non-conformances on this lot number.Final micro and sterility tests passed.Added: h6 (patient).Patient code: no code available (3191) is used to capture joint instability and medical device removal.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SMARTSET HV 20G
Common Device Name
BONE CEMENT : BONE CEMENT
Manufacturer (Section D)
DEPUY CMW - 9610921
cornford rd
blackpool IN FY4 4 QQ
UK  FY4 4QQ
MDR Report Key9401086
Report Number1818910-2019-119477
Device Sequence Number2114205
Product Code LOD
UDI-Device Identifier10603295168324
UDI-Public10603295168324
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K023012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2019
Reporter Type Manufacturer
Report Source other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/06/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number3092-020
Device Catalogue Number3092020
Device Lot Number8158656
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 11/06/2019
Supplement Date Received by Manufacturer09/18/2020
Initial Report FDA Received Date12/03/2019
Supplement Report FDA Received Date09/22/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age53 YR
-
-