ABBOTT VASCULAR ARMADA 35 PTA CATHETER; PERIPHERAL DILATATION CATHETER Back to Search Results
Catalog Number B2080-080
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code Pain (1994)
Date of Event 11/07/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Exemption number e2019001.The customer reported the device was discarded.Investigation is not yet complete.A follow up report will be submitted with all additional relevant information.
 
Event or Problem Description
It was reported that the procedure was performed to treat the varicosis of great saphenous vein.During the procedure, an 8x80mm armada 35 balloon ruptured during the second inflation at 8 atmospheres and the patient felt severe pain.The device was immediately replaced with an unspecified one and the patient was given medications as symptomatic treatment.The patient's respiration, heartbeat, and blood pressure remained stable during the entire procedure.There was no adverse patient sequela and no clinically significant delay in the procedure.No additional information was provided.
 
Additional Manufacturer Narrative
Exemption number e2019001-permits numbering sequence to begin with 10000, to avoid duplication of report numbers due to process transition.There may be gaps in numbering for reports submitted during the transition period.The incident information was reviewed; however, the product was not returned to abbott vascular for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar incidents reported from this lot.The device was prepped prior to use with no issue/ leak noted.Additionally, no balloon ruptured were reported during the first inflation which would suggest that the device was not damaged and functioning as intended.The investigation determined the reported balloon rupture appears to be related to circumstances of the procedure.Based on the reported information, it is likely the balloon became compromised and/or damaging during the first inflation against the anatomy and/or other devices used resulting in the balloon rupture during the second inflation.The reported patient effect of pain is listed in armada 35 instructions for use as a known patient effect of coronary stenting procedures.A conclusive cause for the reported patient effect of pain, and the relationship to the product, if any, cannot be determined.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARMADA 35 PTA CATHETER
Common Device Name
PERIPHERAL DILATATION CATHETER
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
MDR Report Key9404895
Report Number2024168-2019-14067
Device Sequence Number1711390
Product Code LIT
UDI-Device Identifier08717648155451
UDI-Public08717648155451
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K111899
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/26/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2022
Device Catalogue NumberB2080-080
Device Lot Number90725G1
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 11/11/2019
Supplement Date Received by Manufacturer12/06/2019
Initial Report FDA Received Date12/03/2019
Supplement Report FDA Received Date12/26/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-