Model Number 72404252-10
Device Problems Collapse (1099); Inflation Problem (1310); Defective Device (2588)
Patient Problem Capsular Contracture (1761)
Event Date 11/27/2019
Event Type  Injury  
Manufacturer Narrative
Model number/catalog number: 72404155, serial number: null ,batch/lot number: 1000325389, model/catalog description reservoir: 65 ml pc/iz.
 
Event Description
It was reported that the patient experienced a hard time pumping and inflatable penile prosthesis (ipp).A surgical procedure was performed in which the existing pump was removed and replaced with a new one.The patient did not experience any further complications.It was further reported that the patient was having difficulty inflating the device due to a capsule that formed around the pump.The device also presented a "sticky pump" as it would pump once or twice and then remained flat which caused the physician and patient to be unhappy with the outcome, leading to the procedure.The onset of the symptoms was shortly after ipp implantation.The patient was said to be good after the procedure.No more information available at the moment.Should additional information become available, it will be provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE
Type of Device
DEVICE IMPOTENCE MECHANICAL/HYDRAULIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
10700 bren road w
minnetonka MN 55343
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
10700 bren road w
minnetonka MN 55343
Manufacturer Contact
alyson harris
10700 bren road w
minnetonka, MN 55343
4083953452
MDR Report Key9484276
MDR Text Key171780114
Report Number2183959-2019-68200
Device Sequence Number1
Product Code FHW
UDI-Device Identifier00878953009810
UDI-Public00878953009810
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
N970012
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Physician
Type of Report Initial
Report Date 12/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/17/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date08/18/2021
Device Model Number72404252-10
Device Catalogue Number72404252-10
Device Lot Number1000318893
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/27/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/19/2019
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age76 YR
-
-