Model Number 0165L22
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.The device was not returned.
 
Event or Problem Description
It was reported that the catheter did not drain properly, which caused urine to leak around it.The balloon filled unevenly, and when deflating after being filled with 10cc, only 3cc came out.No medical intervention was required.
 
Additional Manufacturer Narrative
The device was not returned for evaluation.A potential root cause could be due to "balloon molding".The device history record was reviewed and found nothing that could have caused or contributed to the reported event.As the catheter was inflated with the correct amount of ccs (10), the reported event would most likely not be caused by the user.Therefore a labeling review was not completed.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Event or Problem Description
It was reported that the catheter did not drain properly, which caused urine to leak around it.The balloon filled unevenly, and when deflating after being filled with 10cc, only 3cc came out.No medical intervention was required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDEX® LUBRICATH® FOLEY CATHETER
Common Device Name
5 CC LUBRICATH
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key9497984
Report Number1018233-2019-08118
Device Sequence Number2897897
Product Code EZC
UDI-Device Identifier00801741017513
UDI-Public(01)00801741017513
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K910846
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source consumer,distributor,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/10/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date12/31/2023
Device Model Number0165L22
Device Catalogue Number0165L22
Device Lot NumberNGDS0361
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 11/26/2019
Supplement Date Received by Manufacturer02/02/2020
Initial Report FDA Received Date12/19/2019
Supplement Report FDA Received Date02/10/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-