CORDIS CORPORATION POWERFLEX P3 F5 5X4 40; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Catalog Number 4205040T
Medical Device Problem Code Burst Container or Vessel (1074)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/09/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The 5f 5mm x 4mm x 40cm powerflex p3 percutaneous transluminal angioplasty (pta) dilatation catheter was inflated in the anatomic part with stenosis; however, it ruptured within its nominal pressure.This was a shunt percutaneous transluminal angioplasty (pta) case and was completed using a new non-cordis balloon catheter.There was no reported patient injury.The intended procedure was anastomotic stenosis which has severe acute angulation.The lesion had ninety nine percent of stenosis and no calcification.The device was stored, handled and prepped per the instructions for use (ifu).There was no difficulty removing the product from the hoop, the protective balloon cover, the stylet or any of the sterile packaging components.There were no kinks or other damages noted prior to inserting the product into the patient.The catheter was passed with finger support from the body surface.The contrast to saline ratio was 1:1.A cordis indeflator was used successfully with other devices.There was no resistance/friction while inserting the balloon through the rotating hemostatic valve or through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.The product was removed intact (in one piece) from the patient.The device was not returned for analysis as it was discarded.A product history record (phr) review of lot 82160256 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿balloon burst-at/below rbp¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.The procedure performed was a shunt percutaneous transluminal angioplasty (pta) case.Arteriovenous shunts are often scarred and fibrous in nature and therefore often resistant to balloon expansion increasing the likelihood of damage to the balloon.However, without the return of the device for analysis it is difficult to draw a clinical conclusion between the device and the event reported.According to the instructions for use ¿if resistance is met during manipulation, determine the cause of the resistance before proceeding.Balloon pressure should not exceed the rated burst pressure.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence), will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over pressurization.Use only the recommended balloon inflation medium.Never use air or any gaseous medium to inflate the balloon.¿ neither the phr nor the information available suggests a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
 
Event or Problem Description
As reported, the 5f 5 x 4 mm x 40 cm powerflex p3 percutaneous transluminal angioplasty (pta) dilatation catheter was inflated in the anatomic part with stenosis however, it ruptured within its nominal pressure.The procedure completed using a new non-cordis balloon catheter.There was no reported patient injury.This was a shunt percutaneous transluminal angioplasty (pta) case.The device was stored and handled per the instructions for use (ifu).The device was prepped according to the ifu.The intended procedure was anastomotic stenosis which has severe acute angulation.The lesion had ninety nine percent of stenosis and no calcification.There was no difficulty removing the product from the hoop.There was no difficulty removing the protective balloon cover.There was no difficulty removing the stylet or any of the sterile packaging components.There were no kinks nor other damages noted prior to inserting the product into the patient.The catheter was passed with finger support from the body surface.The contrast to saline ratio was 1:1.A cordis indeflator was used.The same indeflator was used successfully with other devices.There was no resistance/friction while inserting the balloon through the rotating hemostatic valve.There was no resistance/friction while inserting the balloon through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.The product was removed intact (in one piece) from the patient.The device will not be returned for analysis as it was discarded.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POWERFLEX P3 F5 5X4 40
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
CORDIS CORPORATION
14201 nw 60th ave
miami lakes FL 33014
MDR Report Key9524551
Report Number9616099-2019-03434
Device Sequence Number16836519
Product Code LIT
UDI-Device Identifier20705032004265
UDI-Public20705032004265
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K032737
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 12/27/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2021
Device Catalogue Number4205040T
Device Lot Number82160256
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/10/2019
Initial Report FDA Received Date12/27/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-