• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: AVANOS MEDICAL INC. MIC-KEY LOW-PROFILE GASTROSTOMY FEEDING TUBE - 12 FR, 1.7 CM; DH EF BALLOON TUBES PRODUCTS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AVANOS MEDICAL INC. MIC-KEY LOW-PROFILE GASTROSTOMY FEEDING TUBE - 12 FR, 1.7 CM; DH EF BALLOON TUBES PRODUCTS Back to Search Results
Model Number 0120-12-1.7
Medical Device Problem Code Pressure Problem (3012)
Health Effect - Clinical Code Cellulitis (1768)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The actual complaint product was not returned for evaluation.A review of the device history record is not possible as no lot number was provided.Root cause could not be determined.All information reasonably known as of 27-dec-2019 has been included in this health authority report.Should additional information be obtained, a follow-up health authority report will be provided.The information provided by avanos medical, inc.Represents all of the known information at this time.Avanos medical, inc.Has no independent knowledge of the event reported but is relaying the information that was provided by the user facility where the incident occurred.This product incident is documented in the avanos medical, inc.Complaint database and identified as complaint (b)(4).
 
Event or Problem Description
Avanos medical, inc.Received a single report that referenced five different incidences, which were associated with separate units, involving five different events.This is the second of five reports.Refer to 9611594-2019-00269 for the first event.Refer to 9611594-2019-00271 for the third event.Refer to 9611594-2019-00272 for the fourth event.Refer to 9611594-2019-00273 for the fifth event.It was reported the patient experienced skin breakdown and pressure under the newly placed mic-key gastrostomy tube.The surgeons placing the device are disagreeing with the wound ostomy team that these are pressure related injuries.However, the wound ostomy care nurse (wocn) team is staging it as a pressure injury (cellulitis).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MIC-KEY LOW-PROFILE GASTROSTOMY FEEDING TUBE - 12 FR, 1.7 CM
Common Device Name
DH EF BALLOON TUBES PRODUCTS
Manufacturer (Section D)
AVANOS MEDICAL INC.
5405 windward parkway
alpharetta GA 30004
MDR Report Key9528453
Report Number9611594-2019-00270
Device Sequence Number2769272
Product Code KNT
UDI-Device Identifier00350770948317
UDI-Public00350770948317
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
K043114
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 12/28/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number0120-12-1.7
Device Catalogue Number109483102
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/04/2019
Initial Report FDA Received Date12/28/2019
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-