| Model Number |
M00583190 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
12/12/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental mdr will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a truetome dreamwire 44 was used in the common bile duct (cbd) during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2019.According to the complainant, during the procedure, the truetome dreamwire 44 preloaded was "intruduced" to a biopsy channel to perform a sphincterotomy, the physician noticed that the cutting wire was detached from the catheter during wire tensioning.Reportedly, no part of the device was detached inside the patient.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a truetome dreamwire 44 was used in the common bile duct (cbd) during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2019.According to the complainant, during the procedure, the truetome dreamwire 44 preloaded was intruduced to a biopsy channel to perform a sphincterotomy, the physician noticed that the cutting wire was detached from the catheter during wire tensioning.Reportedly, no part of the device was detached inside the patient.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h6 (device codes): the problem code 1069 captures the reportable event of cutting wire broken.Block h10: visual examination of the returned device revealed that the cutting wire was broken, bent and blackened.There was no other issue noted.The complaint was consistent with the reported event of cutting wire broke.It is most likely that a peak of voltage could have caused the failures noted or if the device was not in contact with the tissue when it was energized.Therefore, the most probable root cause is adverse event related to procedure since the adverse event occurred during the procedure and the device had no influence on event.A review of the device history record (dhr) was performed and confirmed that this device met all material, assembly and performance specifications at the time of release to distribution.A labeling review was performed and from the information available, this device was used per the directions for use (dfu)/product label.
|
| |
|