• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC 11.0MM TI HELICAL BLADE 100MM; ROD,FIXATION,INTRAMEDULLARY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC 11.0MM TI HELICAL BLADE 100MM; ROD,FIXATION,INTRAMEDULLARY Back to Search Results
Model Number 456.305
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Unspecified Infection (1930); No Code Available (3191)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Complainant part is not expected to be returned for manufacturer review/ investigation.Part number: 456.305, lot number: 6191314, part manufacture date: n/a, manufacturing location: n/a, part expiration date: n/a, nonconformance noted: n/a.A review of the device history record could not be performed as the product was not returned and the lot number provided does not match the part number.Product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.(b)(4).Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2020 the patient underwent the removal of bilateral trochanteric fixation nail advanced (tfna) nails in both right and left legs due to non-union and infection.For the right leg, one (1) titanium cannulated trochanteric fixation nail, one (1) helical blade, and two (2) unknown 5.0mm screws were removed.For the left leg, one (1) titanium cannulated trochanteric fixation nail, one (1) end cap, one (1) helical blade, and one (1) unknown 5.0mm screw were removed.The right limb incurred a secondary fracture of the proximal femur upon the nail removal.This fracture will be addressed at a later date.There was no surgical delay.The devices were removed and the procedure was successfully completed.This report is for one (1) 11.0mm ti helical blade 100mm.This is report 2 of 8 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
11.0MM TI HELICAL BLADE 100MM
Common Device Name
ROD,FIXATION,INTRAMEDULLARY
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key9661559
Report Number2939274-2020-00617
Device Sequence Number19663107
Product Code HSB
UDI-Device Identifier10886982226716
UDI-Public(01)10886982226716
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
K011857
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2020
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number456.305
Device Catalogue Number456.305
Device Lot Number6191314
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/13/2020
Initial Report FDA Received Date02/03/2020
Patient Sequence Number1
-
-