Model Number 1504-10-103
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Adhesion(s) (1695); Pain (1994); Discomfort (2330); Injury (2348); Limited Mobility Of The Implanted Joint (2671); No Code Available (3191)
Date of Event 11/19/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Initial reporter occupation: lawyer.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
The patient underwent a left knee revision due to pain, discomfort, stiffness, decreased range of motion, and adhesions.The surgeon noted tibial tray mispositioning with slight overhang as well as loosening at the cement to implant interface.The femoral component was loose at the bone to cement interface with slight bone loss of the lateral femoral condyle.The surgeon reported wear on both the tibial tray and tibial insert.The patella component was well-fixed and retained.Depuy cement was used during the primary operation.Doi: (b)(6) 2016; dor: (b)(6) 2019; left knee.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: product complaint # (b)(4).Investigation summary
=
> no device associated with this report was received for examination.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ATTUNE PS FEM LT SZ 3 CEM
Common Device Name
ATTUNE IMPLANT : KNEE FEMORAL
Manufacturer (Section D)
DEPUY IRELAND - 9616671
loughbeg ringaskiddy co.
cork
EI 
MDR Report Key9672056
Report Number1818910-2020-04002
Device Sequence Number11455144
Product Code JWH
UDI-Device Identifier10603295041603
UDI-Public10603295041603
Combination Product (Y/N)N
Initial Reporter StateLA
Initial Reporter CountryUS
PMA/510(K) Number
K111433
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2016
Device Explanted Year2019
Reporter Type Manufacturer
Report Source other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/22/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date10/31/2023
Device Model Number1504-10-103
Device Catalogue Number150410103
Device Lot Number7784232
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/22/2020
Supplement Date Received by Manufacturer03/12/2020
Initial Report FDA Received Date02/05/2020
Supplement Report FDA Received Date03/16/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ATTUNE MEDIAL ANAT PAT 29MM
Outcome Attributed to Adverse Event Required Intervention;
Patient Age66 YR
-
-