As reported by united kingdom national joint registry (uknjr), this (b)(6) y/o (bmi=25), male patient underwent primary total prosthetic replacement using cement of the left knee via medial parapatellar approach on (b)(6) 2009.The indication for the index procedure was osteoarthritis.On (b)(6) 2019, approximately 121 months post implantation, the patient underwent revision due to osteolysis of the tibia (¿lysistibia¿).Follow-ups for additional information cannot be performed for this complaint, information was submitted as complete by the united kingdom national joint registry (uknjr); there is no identification of facilities or surgeons.All available information about the event and/or patient has been provided.These devices are used for treatment not diagnosis.It is found in a review of the labeling and ifu 700-096-004, osteolysis is a known device specific risk, which may require a second surgical intervention or revision.As part of the preoperative assessment, the surgeon must ensure that no biological, biomechanical, or other factors exist that might adversely affect the surgery and/or postoperative period.Revisions or surgical interventions are a known complication found in joint replacements.All patients should be instructed on the limitations of the prosthesis and the possibility of subsequent surgery.The patient should be cautioned to monitor activities and protect the replaced joint from unreasonable stresses and follow the written instructions of the physician with respect to follow-up care and treatment.The surgeon must be fully knowledgeable about all aspects of the surgical technique to use the implants in accordance with the indications and contraindications and be trained according to the proper use of the system instrumentation and implants.It is a known complication that a patient¿s age, weight, or activity level would cause the surgeon to expect early failure of the system.As noted in ¿why are total knee arthroplasties failing today¿has anything changed after 10 years?¿, the top five reasons for total knee arthroplasty revision/surgical intervention account for approximately 85% of the reasons that drive revision/surgical intervention.The failure mechanisms are as follows: 39.9% for loosening; 27.4% for infection; 7.35% for instability; 4.7% for periprosthetic fracture; and 4.5 % for arthrofibrosis.In early revisions (less than two years) infection was found to be the most common failure mechanism and late revisions show aseptic loosening as the most common reason.1 1.Sharkey, p.L.(2014, september).Why are total knee arthroplasties failing today¿has anything changed after 10 years?; the journal of arthroplasty, 29.It is known that bone mineral density at a total knee arthroplasty will decrease within several months post implant.Bone loss density can reach about 23% within one year of the post-op period.Values are dependent on the preoperative/post-surgical mechanical alignment, and the assessment method.Loss of the bone density post-op is found to be the result of the surgical procedure, peri-operative inflammation and bone remodeling associated with postoperative alterations to the mechanical load.2 2.Gallo, j.G.(2013, september).Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.; retrieved from https://www.Ncbi.Nlm.Nih.Gov/pmc/articles/pmc4003873/.Based on review of all available information, there is no evidence to suggest that the reported event is related to any device design or manufacturing issues.The event reported was likely the result of patient conditions.There has been no patient medical history/information provided; therefore, the patient risk/clinical factors cannot be assessed.This submission represents 1 of 163 events identified via active surveillance activities utilizing data form the united kingdom national joint registry (uknjr).Follow-ups for additional information cannot be performed for this complaint as the information was submitted as complete by the registry; there is no identification of facilities or surgeons.All available information about the event and/or patient has been provided and it is not possible to obtain any of the devices.Concomitant devices: (cn: 200-04-44, sn: (b)(4)) - optetrak knee system - cemented finned tibial tray - size 4f/4t, (cn: 200-24-11, sn: (b)(4)) ¿ optetrak knee system - cruciate retained (cr) tibial insert - size 4 - 11 mm, (cn: 200-02-35, sn: (b)(4)) - optetrak knee system - three pegs patella - diameter 35 mm, (cn: 049180, sn: (b)(4)) - schering-plough high viscosity| bone cement.
|
|
As reported by united kingdom national joint registry (uknjr), this (b)(6) y/o (bmi=25), male patient underwent primary total prosthetic replacement using cement of the left knee via medial parapatellar approach on (b)(6) 2009.The indication for the index procedure was osteoarthritis.On (b)(6) 2019, approximately 121 months post implantation, the patient underwent revision due to osteolysis of the tibia (¿lysistibia¿).The follow-ups for additional information cannot be performed for this complaint, information was submitted as complete by the united kingdom national joint registry (uknjr); there is no identification of facilities or surgeons.All available information about the event and/or patient has been provided.These devices are used for treatment not diagnosis.Based on review of all available information, there is no evidence to suggest that the reported event is related to any device design or manufacturing issues.The event reported was likely the result of patient conditions.There has been no patient medical history/information provided; therefore, the patient risk/clinical factors cannot be assessed.
|