• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDOS INTERNATIONAL SàRL CH STANDARD 5MM WEDGED VBR 7; POLYMERIC SPINAL FUSION CAGE, NON-STERILE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDOS INTERNATIONAL SàRL CH STANDARD 5MM WEDGED VBR 7; POLYMERIC SPINAL FUSION CAGE, NON-STERILE Back to Search Results
Model Number 187301105
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Skin Irritation (2076)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Product complaint # (b)(4).Exp.Date is unknown.Complainant part is not expected to be returned for manufacturer review/ investigation.The investigation could not be completed; no conclusion could be drawn at the time of filing this report.A review of the device history record has been requested.The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2019, the patient underwent an anterior cervical discectomy and fusion (c6-c7) surgery.Post-surgery, the patient has developed some skin condition and is currently undergoing extended skin patch testing to rule out if the patient is not allergic to any of the metals that were placed into the patient's neck.The surgeon and dermatologist performed extended patch testing and vanadium chloride came back positive out of 80 common patches after 48 hours after surgery.Monitoring with allergists and dermatologists, working together to potentially prescribe medications.The surgeon will discuss whether or not a revision will be necessary after fusion.The patient was implanted with a plate from depuy spine, one screw is from depuy synthes and another one screw is from johnson health and a cage from depuy spine.Concomitant device reported: unknown screws (part # unknown, lot # unknown, quantity 2).This complaint involves six (6) devices.This report is 1 of 6 for (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: h11: corrected data.D4: updated lot number.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h6: investigation summary - product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.H3, h6: device history lot a review of the device history record (dhr) could not be performed as no manufacturing records could be found for this part # 187301105 / lot # 62745a combination.If further information becomes available, this dhr can be revisited.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STANDARD 5MM WEDGED VBR 7
Common Device Name
POLYMERIC SPINAL FUSION CAGE, NON-STERILE
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
MDR Report Key9728849
Report Number1526439-2020-00572
Device Sequence Number2928279
Product Code MQP
UDI-Device Identifier10705034136967
UDI-Public(01)10705034136967
Combination Product (Y/N)N
PMA/510(K) Number
K031635
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Reporter Type Manufacturer
Report Source consumer,other
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/29/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number187301105
Device Catalogue Number187301105
Device Lot Number62745A
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/29/2020
Supplement Date Received by Manufacturer02/24/2020
02/27/2020
Initial Report FDA Received Date02/19/2020
Supplement Report FDA Received Date02/24/2020
03/23/2020
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
BENGAL IMPLANT STD 5MM 7 DEG; QTY 2; QTY 2; SKY 1 LEVEL PLTE 14MM TI
Outcome Attributed to Adverse Event Required Intervention;
Patient Age40 YR
Patient Weight58
-
-