| Model Number |
222223 |
| Medical Device Problem Code |
Dull, Blunt (2407)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
02/07/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported by the sales rep via complaint submission tool that when performing a shoulder rotator cuff repair when the healix awl -ns was being used it was noticed that the laser line was completely dull and was not able to properly locate the depth to mallet.A second 4.75 healix advance kntlss pk that the facility owned was intended to be used however the top of the awl was slightly bent.The procedure was completed using another device.No patient consequence and no surgical delay was reported.No additional information was provided.An email received from the affiliate clarified the second product code 222223, lot 1408002 - healix awl.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: investigation summary: according to the information provided, it was reported that when performing a shoulder rotator cuff repair when the healix awl -ns was being used it was noticed that the laser line was completely dull and was not able to properly locate the depth to mallet.The complaint device was received and inspected.Visual observation showed the laser marks slightly faded, which indicates heavy use.Besides, there are a lot of marks on the device, which makes it look old.The device is reusable, this type of failure is typically observed after the device has been reprocessed multiple times.The complaint can be confirmed to the reported condition since the laser lines were faded and it could be difficult to locate the depth insertion during the procedure.The possible route cause could be related to the fair wear and tear due to age and use, reprocessing of this reusable device multiple times over several years and this product could be susceptible to the autoclave process negatively affecting the laser lines.A manufacturing record evaluation was performed for the finished device lot/serial number (b)(6), and no non-conformances were identified.At this point, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.Device history lot: a manufacturing record evaluation was performed for the finished device lot/serial number (b)(6), and no non-conformances were identified.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: d10, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|