| Model Number |
72204392 |
| Medical Device Problem Code |
Material Separation (1562)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
01/30/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
International zip code: (b)(6).
|
| |
|
Event or Problem Description
|
|
It was reported that during posterior lateral corner surgery the screw broke into small pieces inside the joint.The broken pieces were removed with forceps.The procedure was successfully completed without significant delay using a back-up device.No patient injury or other complications were reported.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: one 72204392 6x25mm biosure regenesorb screw was used for treatment but was not returned for evaluation.Due to product unavailability investigation was limited.If further information becomes available, the complaint may be revisited.Factors that may affect device performance include: device ability, surgical ability, procedure location and tissue and patient condition.Influences that could compromise product performance or integrity that are unrelated to manufacture include: 1.Adherence to the instructions for use recommendations.2.Use of other than recommended prep instrument size or types.3.Getting entangled with other instruments or devices.4.Stripping or over-torque.5.Damaged prep instruments.6.Unexpected bone density/condition.Review of instruction for use documentation confirms instructions, precautionary statements and recommendations for proper use of product.Prep per the instructions for use recommendation is critical for ease of insertion and successful anchoring.Per instructions for use: ¿use of a driver other than the appropriate biosure driver may result in breakage of the screw.Breakage of the screw or loss of fixation may occur if the insertion site is not prepared properly.Inspect to confirm that the interference screw is fully seated onto the driver prior to insertion.If the interference screw is not properly seated on the driver, damage to or breakage of the screw may result.Failure to fully seat the screw may result in breakage of the screw.The biosure tap is recommended for use with bone-tendon-bone grafts prior to inserting the interference screw.Complaint history review indicated no similar allegations for the lot number reported.Batch review did not indicate a condition or product/procedure failure that supported the allegation.Product met specifications upon release to distribution.No further investigation is warranted at this time.
|
| |
|
Search Alerts/Recalls
|