| Model Number |
143110 |
| Medical Device Problem Code |
Fracture (1260)
|
| Health Effect - Clinical Codes |
Foreign Body In Patient (2687); No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
01/28/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
As part of the normal complaint follow-up, an evaluation of the event has been initiated by mako surgical.A supplemental report will be submitted when additional information becomes available.
|
| |
|
Event or Problem Description
|
|
During the tka operation using mako, drilled the bone pin to the femoral shaft to place the femoral array.The tip of the pin broke when it reached the second cortex.Replaced with another pin, but it also broke.The third pin could be placed, and operation was completed.However, after operation, x-ray confirmed three broken piece remained in the patient bone.Those could not be removed, so those were left and operation was finished.
|
| |
|
Event or Problem Description
|
|
During the tka operation using mako, drilled the bone pin to the femoral shaft to place the femoral array.The tip of the pin broke when it reached the second cortex.Replaced with another pin, but it also broke.The third pin could be placed, and operation was completed.However, after operation, x-ray confirmed three broken piece remained in the patient bone.Those could not be removed, so those were left and operation was finished.
|
| |
|
Additional Manufacturer Narrative
|
|
Update to d2.Reported event: during the tka operation using mako, drilled the bone pin to the femoral shaft to place the femoral array.The tip of the pin broke when it reached the second cortex.Replaced with another pin, but it also broke.The third pin could be placed, and operation was completed.However, after operation, x-ray confirmed three broken piece remained in the patient bone.Those could not be removed, so those were left and operation was finished.Product evaluation and results: visual inspection did not confirms the broken tip of the bone pin.Product history review: review of the device history records indicate 249 devices were manufactured and accepted into final stock on (b)(6) 2019.No non-conformances were identified during inspection.Complaint history review: a review of complaints in catsweb and trackwise related to p/n 143110, l/n w66568 shows no additional complaints related to the failure in this investigation.Conclusions: the failure of the broken bone pin from the tip cannot be confirmed via inspection.No additional investigation or specific actions are required.If additional information is received then the complaint will be reopened.
|
| |
|