MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION NC QUANTUM APEX; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION NC QUANTUM APEX; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number 6532
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 02/26/2020
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that a balloon burst occurred.A 15mm x 3.50mm nc quantum apex balloon was advanced to the target lesion, and after inflation the balloon burst.The procedure was completed with another of the same device.No patient complications resulted in relation to this event and the patient condition after the procedure was good.
 
Additional Manufacturer Narrative
Device evaluated by mfr: returned product consisted of an nc quantum apex balloon catheter.The shaft, hypotube, tip and balloon were microscopically and visually examined.There were numerous kinks.There was contrast and blood in the inflation lumen and balloon.The balloon was loosely folded.The device was prepped with an inflation device filled with water and connected to the inflation port to inflate the device.There was a pinhole at the proximal marker band.There was no marker band damage detected.Inspection of the remainder of the device presented no other damage or irregularities.Product analysis confirmed the reported balloon ruptured.
 
Event or Problem Description
It was reported that a balloon burst occurred.A 15mm x 3.50mm nc quantum apex balloon was advanced to the target lesion, and after inflation the balloon burst.The procedure was completed with another of the same device.No patient complications resulted in relation to this event and the patient condition after the procedure was good.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC QUANTUM APEX
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key9880147
Report Number2134265-2020-03471
Device Sequence Number3419114
Product Code LOX
UDI-Device Identifier08714729783398
UDI-Public08714729783398
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K121667
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/27/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/04/2022
Device Model Number6532
Device Catalogue Number6532
Device Lot Number0024713081
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/25/2020
Initial Date Received by Manufacturer 03/02/2020
Supplement Date Received by Manufacturer04/02/2020
Initial Report FDA Received Date03/25/2020
Supplement Report FDA Received Date04/27/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-