ADVANCED STERILIZATION PRODUCTS CYCLESURE 24 BIO INDICATOR; INDICATOR, BIOLOGICAL Back to Search Results
Model Number 14324
Medical Device Problem Code Appropriate Device Problem Term/Code Not Available (3191)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/05/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Initial reporter phone #: (b)(6).(b)(4).Test specifications for product release were met.No issues were observed in the dhr that would contribute to the complaint.Asp complaint ref #: (b)(4).
 
Event or Problem Description
A customer reported a positive result with a cyclesure® 24 biological indicator (bi) after a completed sterrad® cycle.The affected load was released and used on a patient.There was no report of infection, injury or harm to patient(s) associated with this issue.Although there is no report of patient injury or harm and no prior incidents have resulted in serious injury, advanced sterilization products (asp) has determined in this situation sterility cannot be assured.Therefore, as a matter of policy asp had decided to report all incidents of positive cyclesure® 24 biological indicators when the load has been released and used on patient(s) prior to reprocessing.
 
Additional Manufacturer Narrative
It was initially reported the load from the suspected positive bi was released and used on a patient prior to reprocessing the load.However, new information was received from the affiliate stating that the load was released but not used on a patient.Therefore, this file is no longer deemed a reportable malfunction since there is no risk to patients.Asp complaint ref #: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CYCLESURE 24 BIO INDICATOR
Common Device Name
INDICATOR, BIOLOGICAL
Manufacturer (Section D)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
MDR Report Key9898407
Report Number2084725-2020-00026
Device Sequence Number2788849
Product Code FRC
UDI-Device Identifier10705037016211
UDI-Public10705037016211
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K994055
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2020
Device Model Number14324
Device Catalogue Number14324
Device Lot Number16119028
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 03/06/2020
Supplement Date Received by Manufacturer06/10/2020
Initial Report FDA Received Date03/30/2020
Supplement Report FDA Received Date06/17/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-