• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SORIN GROUP ITALIA S.R.L. CARBOMEDICS OPTIFORM PROSTHETIC HEART VALVE, MITRAL; MECHANICAL HEART VALVE PROSTHESIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SORIN GROUP ITALIA S.R.L. CARBOMEDICS OPTIFORM PROSTHETIC HEART VALVE, MITRAL; MECHANICAL HEART VALVE PROSTHESIS Back to Search Results
Model Number CPHV
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Thrombosis (2100); No Information (3190)
Date of Event 02/02/2020
Type of Reportable Event Serious Injury
Event or Problem Description
On (b)(6) 2020 a patient received a carbomedics optiform f7-027 mechanical heart valve as part of an mvr.The manufacturer was notified that the device was explanted on (b)(6) 2020 and replaced with a carbomedics standard m7-031 mechanical heart valve.No further information was received.
 
Additional Manufacturer Narrative
On (b)(6) 2020 a patient received a carbomedics optiform f7-027 mechanical heart valve as part of an mvr.The manufacturer was notified that the device was explanted on (b)(6) 2020 and replaced with a carbomedics standard m7-031 mechanical heart valve.The manufacturer received additional information from the site identifying the following.The optiform thrombosis occurred in the context of apparently therapeutic inr (2.5).At the time of reoperation, the device was covered in a thin film of pale white thrombus (possibly fibrin).This was completely cleaned off in situ so the leaflets could be tested and freely mobile without restrictions.Following neutralization of the heparin with protamine, the device clotted off again in the operating room.Returned back on pump with heparin and replaced the mitral valve with a standard device (larger size).No issues this time.Patient is alive and well with thrombosis service aiming for higher inr.(pt was a double valve case with aortic valve replacement done at initial surgery).Pathology identified thrombus on device.No mechanical comments made.It was identified by the patients family that the patient never bruised as a child from injuries and the site suspected a procoagulant state that was not clearly identified, hence why the patient has been quickly anticoagulated post-operatively.
 
Event or Problem Description
On (b)(6) 2020 a patient received a carbomedics optiform f7-027 mechanical heart valve as part of an mvr.The manufacturer was notified that the device was explanted on (b)(6) 2020 and replaced with a carbomedics standard m7-031 mechanical heart valve.The manufacturer received additional information from the site identifying the following.The optiform thrombosis occurred in the context of apparently therapeutic inr (2.5).At the time of reoperation, the device was covered in a thin film of pale white thrombus (possibly fibrin).This was completely cleaned off in situ so the leaflets could be tested and freely mobile without restrictions.Following neutralization of the heparin with protamine, the device clotted off again in the operating room.Returned back on pump with heparin and replaced the mitral valve with a standard device (larger size).No issues this time.Patient is alive and well with thrombosis service aiming for higher inr.(pt was a double valve case with aortic valve replacement done at initial surgery).Pathology identified thrombus on device.No mechanical comments made.It was identified by the patients family that the patient never bruised as a child from injuries and the site suspected a procoagulant state that was not clearly identified, hence why the patient has been quickly anticoagulated post-operatively.
 
Additional Manufacturer Narrative
Based on the additional information received the valve displayed no mechanical issues or relationships to the event.The thrombosis was hypothesized to be a result of patient related factors.As such no further investigations will be performed at this time.The conclusion of the manufacturers analysis is thus cause cannot be traced to device : adverse event related to patient condition.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CARBOMEDICS OPTIFORM PROSTHETIC HEART VALVE, MITRAL
Common Device Name
MECHANICAL HEART VALVE PROSTHESIS
Manufacturer (Section D)
SORIN GROUP ITALIA S.R.L.
strada crescentino snc
saluggia, vc
MDR Report Key9914524
Report Number1718850-2020-01057
Device Sequence Number16316209
Product Code LWQ
UDI-Device Identifier08022057012852
UDI-Public(01)08022057012852(240)F7-027(17)230211
Combination Product (Y/N)N
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2020
Reporter Type Importer
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 06/01/2020
Report Date (Section F) 03/04/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/02/2023
Device Model NumberCPHV
Device Catalogue NumberF7-027
Was the Report Sent to FDA? No
Distributor Facility Aware Date03/04/2020
Device Age14 MO
Event Location Hospital
Date Report to Manufacturer03/04/2020
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer03/04/2020
03/04/2020
Initial Report FDA Received Date04/01/2020
Supplement Report FDA Received Date05/23/2020
06/01/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age60 YR
-
-