• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION SUPER SHEATH INTRODUCER SHEATH; INTRODUCER, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION SUPER SHEATH INTRODUCER SHEATH; INTRODUCER, CATHETER Back to Search Results
Model Number 28182
Medical Device Problem Code Device Contamination with Chemical or Other Material (2944)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 04/01/2020
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that there was moisture in the packaging.The 5 fr x 11 cm super sheath introducer sheath was selected for use.During preparation, moisture was noted in the internal packaging and there was concern regarding the sterility of the sheath.A new super sheath introducer sheath with a different batch number was used to complete the procedure.No patient was involved at the time of the event.
 
Event or Problem Description
It was reported that there was moisture in the packaging.The 5 fr x 11 cm super sheath introducer sheath was selected for use.During preparation, moisture was noted in the internal packaging and there was concern regarding the sterility of the sheath.A new super sheath introducer sheath with a different batch number was used to complete the procedure.No patient was involved at the time of the event.
 
Additional Manufacturer Narrative
Device evaluated by manufacturer: the product was returned inside the sealed sterile pouch.Visual examination confirmed moisture was adhered to the inside of the sterile pouch.Further examination confirmed that the moisture was silicone oil.Silicone oil was also observed surrounding the hemostatic valve.Silicone oil is used during the manufacturing process and applied to the hemostatic valve.The oil facilitates smooth operation of the valve during use.Silicone oil is not used anywhere else during the manufacturing process.The amount of silicone oil applied to the hemostatic valve is minimal, but not constant.If manufacturing personnel determines that excess silicone oil has been applied during the set-up of the sheath and dilator, or if silicone oil deposits are observed in areas that come into contact with the sterilization bag before the product is placed in the sterilization bag, the manufacturing procedure requires to wipe off the silicone oil deposits.In addition, final visual inspection of foreign material is conducted at the package to shelf carton.It is thought that the silicone oil applied to the sheath valve came into contact with the inner sterile pouch due to vibration during transportation and storage condition.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SUPER SHEATH INTRODUCER SHEATH
Common Device Name
INTRODUCER, CATHETER
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key9929125
Report Number2134265-2020-04384
Device Sequence Number690459
Product Code DYB
UDI-Device Identifier14543527181638
UDI-Public14543527181638
Combination Product (Y/N)N
Initial Reporter StateNH
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 05/20/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/30/2022
Device Model Number28182
Device Catalogue Number28182
Device Lot Number19J07BA
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/21/2020
Initial Date Received by Manufacturer 04/01/2020
Supplement Date Received by Manufacturer05/11/2020
Initial Report FDA Received Date04/06/2020
Supplement Report FDA Received Date05/20/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-