Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
It was reported that on march 16, 2020, two (2) cannulated stardrive screwdrivers were twisted and stripped; the ends of it are twisted where it would contact a screw.One (1) locking pliers-long was damaged and would not grip onto the item trying to be removed.There was no patient involvement.This report is for a cannulated stardrive screwdriver shaft/t15.This is report 2 of 2 for (b)(4).
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h4, h6: part number: 03.240.002.Synthes lot number: h278613.Supplier lot number: n/a.Release to warehouse date: 24apr2017.Expiration date: n/a.Manufactured by synthes monument.No ncrs were generated during production.Review of the device history record showed that there were no issues during the manufacture of this product, and any subcomponents, which would contribute to this complaint condition.Visual inspection: the cannulated stardrive screwdriver shaft/t15 (part # 03.240.002, lot # h278613) was received at us customer quality (cq).The distal tip was twisted in the direction of tightening.The twisted condition of the tip would render the device inoperable.The part#/lot# etch was worn and faded.The damage was consistent as an end of life indicator for the device.No other issues were identified during inspection.The received condition was consistent with the complaint condition thus the complaint was confirmed.Conclusion: after a visual inspection per guidance, it is determined that the reusable instrument is worn from repeated use and servicing; therefore, further investigation for the reported complaint device is not required.During the investigation, no product design or manufacturing issues were observed that may have contributed to the complaint condition; therefore, further corrective and/or preventive action is not required.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post market safety surveillance activities.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|