• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TISSUE SCIENCE LABORATORIES PERMACOL; MESH, SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TISSUE SCIENCE LABORATORIES PERMACOL; MESH, SURGICAL Back to Search Results
Model Number P151828
Medical Device Problem Codes Degraded (1153); Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Adhesion(s) (1695); Purulent Discharge (1812); Erythema (1840); Fistula (1862); Granuloma (1876); Failure of Implant (1924); Unspecified Infection (1930); Inflammation (1932); Necrosis (1971); Pain (1994); Seroma (2069); Injury (2348); Impaired Healing (2378); Obstruction/Occlusion (2422); Fluid Discharge (2686); Unspecified Tissue Injury (4559); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
The patient¿s attorney alleged a deficiency against the device.The product was used for therapeutic treatment of an umbilical hernia.It was reported that after the implant, the patient experienced seroma, failure of mesh, infection, and fistulizing mesh.Post-operative patient treatment included revision surgery, wound vac, and numerous irrigations and debridements of wound/infection.
 
Additional Manufacturer Narrative
Additional info: a3a, b5, b7, d8, e1 (street 1, city, region, postal code), h6 (patient codes, device codes, ime e2402: sinus tract, loss of domain), <(>&<)> additional codes medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
The patient¿s attorney alleged a deficiency against the device.The product was used for therapeutic treatment of an umbilical hernia.It was reported that after the implant, the patient experienced seroma, failure of mesh, infection, fistulizing mesh, fat necrosis, draining sinus tract, granuloma, adhesions, open wound, bowel obstruction, purulent drainage, inflammation, pain, suffering, erythema, loss of domain.Post-operative patient treatment included revision surgery, wound vac, numerous irrigations and debridement of wound/infection, incision drainage of seroma, mesh removal, exploratory laparotomy, hernia repair mesh, lysis of adhesions, ileocecectomy, abdominal washout, ileal colectomy, small bowel resection.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERMACOL
Common Device Name
MESH, SURGICAL
Manufacturer (Section D)
TISSUE SCIENCE LABORATORIES
victoria house, victoria road
aldershot, hampshire GU11 1EJ
GB  GU11 1EJ
Manufacturer (Section G)
TISSUE SCIENCE LABORATORIES
victoria house, victoria road
aldershot, hampshire GU11 1EJ
GB   GU11 1EJ
Manufacturer Contact
mike bocchino
8200 coral sea st ne
mounds view,mn, CT 55112-4391
8006464633
MDR Report Key9963554
Report Number9617613-2020-00049
Device Sequence Number2785012
Product Code FTM
UDI-Device Identifier10884523000191
UDI-Public10884523000191
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K120605
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2011
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 05/11/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/31/2013
Device Model NumberP151828
Device Catalogue NumberP151828
Device Lot Number09B2907
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/01/2020
Supplement Date Received by Manufacturer04/29/2026
Initial Report FDA Received Date04/15/2020
Supplement Report FDA Received Date05/11/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
PCO3020(LOT#: PHI00564); PCO3020(LOT#: PHI00564)
Outcome Attributed to Adverse Event Required Intervention;
Patient SexFemale
-
-