| Model Number |
254622 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
06/02/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Product complaint #: (b)(4).Device was used for treatment, not diagnosis.Initial reporter phone number: (b)(6).Udi: (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported by the sales rep via phone that during an acl procedure the biointrafix 6-7 mm x 30 mm tprscr broke off, all the pieces were removed from the patient.Another device was used to complete the surgery.There were no adverse consequences to the patient.No additional information could be provided.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.D10, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: investigation summary: according to the information provided, it was reported that during the surgery of acl, the anchor was broken off, all the pieces were removed from patient.The biointrafix tbial was received and evaluated.Visual inspection revealed that the device was broken into multiple pieces and present biological debris.Customer complaint can be confirmed.The possible root cause for issue experienced can be attributed to an excessive force by the surgeon, whether the insertion was off axis during the procedure.However, it cannot be conclusively affirmed. as a potential cause cannot be associated to manufacturing, therefore a manufacturing record evaluation is not required.At this time, no corrective action is required, and no further action is warranted, as the device was placed in long term hold.However, depuy synthes mitek will continue to track any related complaints within this device family to monitor the extent to which this complaint is observed in the field.
|
| |
|