| Model Number |
N/A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Cardiac Arrest (1762); Death (1802); Tachycardia (2095)
|
| Date of Event |
03/17/2020
|
|
Type of Reportable Event
|
Death
|
|
Additional Manufacturer Narrative
|
|
The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) of redw0118 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported that for an infant (b)(6), with a history of bronchiolitis hospitalized in a sheave with non-invasive ventilation support and then discharged to general pediatrics for further treatment.Readmitted for endocarditis with antibiotic treatment required for 6 weeks.Catheter installation on (b)(6) at 5 p.M.To be able to carry out the treatment.Transfusion necessary for the end of a bradycardia then abrupt stop at 10.00 pm (5h after installation), immediately taken care of on compression hemopericardium, tamponade and transfer to intensive care unit, unfavorable development and death the next day at 5 p.M.
|
| |
|
Event or Problem Description
|
|
It was reported that a 5 week old patient was admitted to the hospital in the intensive care unit for bronchiolitis, respiratory syncytial virus, endocarditis with staphylococcus aureus methicilline-sensible.At the time of admission the patient was anemic but otherwise not in any respiratory distress.The cvc was place for antibiotic treatment on (b)(6) 2020.The cvc was placed with some bleeding at the insertion site and the patient was reportedly tachycardic (attributed by the physician to the anemia).Placement was confirmed with x-ray and the tip of the catheter was reportedly in the upper 1/3 of the right atrium.The next day, the patient remained tachycardic related to the anemia.The patient went into cardiac arrest.During resuscitation, a cardiac ultrasound showed circumferential pericardial effusion.Resuscitation efforts, which included pericardial drainage and external cardiac massage were unsuccessful and the patient died.The reported documented cause of death was cardiac arrest due to pericardial tamponade.An autopsy was not performed and the death certificated is reportedly not available.
|
| |
|
Additional Manufacturer Narrative
|
|
H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) of redw0118 showed no other similar product complaint(s) from this lot number.
|
| |
|