MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PRIM TIB BASEPLATE - CEMENTED; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PRIM TIB BASEPLATE - CEMENTED; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO Back to Search Results
Model Number 5520-B-600
Medical Device Problem Code Unstable (1667)
Health Effect - Clinical Codes Pain (1994); Injury (2348); Ambulation or Postural Difficulties (2544); Joint Laxity (4526)
Date of Event 01/04/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Review of the device history records indicate that devices were manufactured and accepted into final stock with no reported discrepancies.There has been another event for the lot referenced.The information in this report was provided by stryker orthopaedics legal affairs department.No additional information is available at this time due to the ongoing litigation.Should additional information become available, the evaluation summary will be submitted in a supplemental report.Reported event: an event regarding instability involving a triathlon baseplate was reported.The event was confirmed through clinician review of the provided medical records.Method & results: product evaluation and results: not performed as no product was returned for evaluation.Clinician review: a review of the provided medical records and x-rays by a clinical consultant indicated: more than minimal and unequal bone restrictions on distal femur and proximal tibia have resulted in an increase in amount of bone resection across the knee that cannot be compensated anatomically by the use of the thinnest available bearing of 9- mm thickness.Initial subclinical instability has increased with time under daily load further and magnified by patient's obesity resulting in clinical instability ultimately requiring revision surgery with increase in constraint across the knee through use of triathlon ts devices.Does the review identify any procedural related factors that contributed to the event? more than minimal and unequal bone resection on distal femur and proximal tibia.Use of a thinner bearing than corresponds with the amount of bone resection.Product history review: indicated all devices were manufactured and accepted into final stock with no reported discrepancies.Complaint history review: there have been no other similar events for the lot referenced.Conclusions: the event of instability was confirmed by clinician review who indicated: more than minimal and unequal bone restrictions on distal femur and proximal tibia have resulted in an increase in amount of bone resection across the knee that cannot be compensated anatomically by the use of the thinnest available bearing of 9- mm thickness.Initial subclinical instability has increased with time under daily load further and magnified by patient's obesity resulting in clinical instability ultimately requiring revision surgery with increase in constraint across the knee through use of triathlon ts devices.Does the review identify any procedural related factors that contributed to the event? more than minimal and unequal bone resection on distal femur and proximal tibia.Use of a thinner bearing than corresponds with the amount of bone resection.No further investigation is required at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Event or Problem Description
It was reported through the communication of an attorney that allegedly the patient was revised due to "failed right total knee arthroplasty".Update: based on the medical review dated 24 march 2020 [.] initial subclinical instability has increased with time under daily load further and magnified by patient's obesity resulting in clinical instability ultimately requiring revision surgery with increase in constraint across the knee through use of triathlon ts devices.
 
Event or Problem Description
No new information.
 
Additional Manufacturer Narrative
Reported event: an event regarding instability involving a triathlon baseplate was reported.The event was confirmed through clinician review of the provided medical records.Method & results: -product evaluation and results: not performed as no product was returned for evaluation.-clinician review: a review of the provided medical records and x-rays by a clinical consultant indicated: more than minimal and unequal bone restrictions on distal femur and proximal tibia have resulted in an increase in amount of bone resection across the knee that cannot be compensated anatomically by the use of the thinnest available bearing of 9- mm thickness.Initial subclinical instability has increased with time under daily load further and magnified by patient's obesity resulting in clinical instability ultimately requiring revision surgery with increase in constraint across the knee through use of triathlon ts devices.More than minimal and unequal bone resection on distal femur and proximal tibia.Use of a thinner bearing than corresponds with the amount of bone resection.An updated med review indicated: "confirmation of event: i can only confirm the primary and revision knee arthroplasties through the medical record which provided reports of x-rays of the primary and revision knee arthroplasty.I cannot confirm the dates.Root cause analysis: the root cause of this event cannot be determined with certainty.The causes of late instability in a total knee arthroplasty are multifactorial including surgical technique, patient lifestyle and activity level as well as bmi.Stretching of the ligament complexes after surgery is not uncommon" -product history review: indicated all devices were manufactured and accepted into final stock with no reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: the event of instability was confirmed by clinician review who indicated: more than minimal and unequal bone restrictions on distal femur and proximal tibia have resulted in an increase in amount of bone resection across the knee that cannot be compensated anatomically by the use of the thinnest available bearing of 9- mm thickness.Initial subclinical instability has increased with time under daily load further and magnified by patient's obesity resulting in clinical instability ultimately requiring revision surgery with increase in constraint across the knee through use of triathlon ts devices.More than minimal and unequal bone resection on distal femur and proximal tibia.Use of a thinner bearing than corresponds with the amount of bone resection.An updated med review indicated: "confirmation of event: i can only confirm the primary and revision knee arthroplasties through the medical record which provided reports of x-rays of the primary and revision knee arthroplasty.I cannot confirm the dates.Root cause analysis: the root cause of this event cannot be determined with certainty.The causes of late instability in a total knee arthroplasty are multifactorial including surgical technique, patient lifestyle and activity level as well as bmi.Stretching of the ligament complexes after surgery is not uncommon" no further investigation is required at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON PRIM TIB BASEPLATE - CEMENTED
Common Device Name
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
arokiya raj
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key9996404
Report Number0002249697-2020-00798
Device Sequence Number4597601
Product Code MBH
UDI-Device Identifier07613327050349
UDI-Public07613327050349
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K141056
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2013
Device Explanted Year2017
Reporter Type Manufacturer
Report Source Other,Consumer
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/28/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/30/2017
Device Model Number5520-B-600
Device Catalogue Number5520-B-600
Device Lot NumberHJZLD
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/27/2020
Supplement Date Received by Manufacturer04/30/2025
Initial Report FDA Received Date04/24/2020
Supplement Report FDA Received Date05/28/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/22/2012
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age56 YR
Patient SexMale
-
-