Date of Entry
|
Specialty Task Group Area
|
Recognition Number
|
Extent of Recognition
|
Standards Developing Organization
|
Standard Designation Number and Date
|
Standard Title (click for recognition information)
|
03/16/2012 |
InVitro Diagnostics |
7-165 |
Complete |
CLSI |
H20-A2 (Replaces H20-A) |
Reference Leukocyte (WBC) Differential Count (Proportional) and Evaluation of Instrumental Methods; Approved Standard - Second Edition |
09/17/2018 |
InVitro Diagnostics |
7-276 |
Complete |
CLSI |
M38 3rd Edition |
Reference Method for Broth Dilution Antifungal Susceptibility Testing of Filamentous Fungi |
09/17/2018 |
InVitro Diagnostics |
7-278 |
Complete |
CLSI |
M27 4th Edition |
Reference Method for Broth Dilution Antifungal Susceptibility Testing of Yeasts |
03/18/2009 |
Software/ Informatics |
13-28 |
Complete |
CLSI |
AUTO9-A |
Remote Access to Clinical Laboratory Diagnostic Devices via the Internet; Approved Standard |
12/19/2022 |
Anesthesiology |
1-159 |
Complete |
ISO |
18778 Second edition 2022-06 |
Respiratory equipment - Particular requirements for basic safety and essential performance of infant cardiorespiratory monitors |
10/04/2010 |
InVitro Diagnostics |
7-212 |
Complete |
CLSI |
EP18-A2 |
Risk Management Techniques to Identify and Control Laboratory Error Sources; Approved Guideline - Second Edition |
12/21/2020 |
Dental/ ENT |
4-272 |
Complete |
ANSI ADA |
Standard No. 63-2013 |
Root Canal Barbed Broaches and Rasps |
06/27/2016 |
Dental/ ENT |
4-202 |
Complete |
ANSI ADA |
Standard No. 58-2010 (R2015) |
Root Canal Files, Type H (Hedstrom) |
01/30/2014 |
ObGyn/ Gastroenterology/ Urology |
9-86 |
Complete |
ISO |
16037 First edition 2002-05-15 (Amendment 1 2011-02-15) |
Rubber condoms for clinical trials - Measurement of physical properties [Including: Amendment (2011)] |
07/09/2014 |
Radiology |
12-273 |
Complete |
IEC |
60825-1 Edition 2.0 2007-03 |
Safety of laser products - Part 1: Equipment classification, and requirements [Including: Technical Corrigendum 1 (2008), Interpretation Sheet 1 (2007), Interpretation Sheet 2 (2007)] |
04/03/2023 |
General II (ES/ EMC) |
19-34 |
Complete |
IEC |
61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements [Including: Corrigendum 1 (2019)]
- Note: This standard is recognized with relevant US national differences applied, see reference #1 in Relevant FDA Guidance and/or Supportive Publication section |
08/21/2017 |
General II (ES/ EMC) |
19-25 |
Complete |
IEC |
62485-1 Edition 1.0 2015-04 |
Safety requirements for secondary batteries and battery installations - Part 1: General safety information. |
08/21/2017 |
General II (ES/ EMC) |
19-26 |
Complete |
IEC |
62485-2 Edition 1.0 2010-06 |
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries. |
08/21/2017 |
General II (ES/ EMC) |
19-27 |
Complete |
IEC |
62485-3 Edition 2.0 2014-07 |
Safety requirements for secondary batteries and battery installations - Part 3: Traction batteries |
08/21/2017 |
General II (ES/ EMC) |
19-28 |
Complete |
IEC |
62485-4 Edition 1.0 2015-01 |
Safety requirements for secondary batteries and battery installations - Part 4: Valve-regulated lead-acid batteries for use in portable appliances |
09/17/2018 |
Physical Medicine |
16-203 |
Complete |
ASME |
A18.1-2017 |
Safety Standard for Platform Lifts and Stairway Chairlifts |
12/19/2022 |
Anesthesiology |
1-154 |
Complete |
ASME |
PVHO-1-2019 |
Safety Standard for Pressure Vessels for Human Occupancy |
01/27/2015 |
General I (QS/ RM) |
5-62 |
Complete |
ANSI ASQ |
Z1.4-2003 (R2018) |
Sampling Procedures and Tables for Inspection by Attributes |
01/27/2015 |
General I (QS/ RM) |
5-48 |
Complete |
ANSI |
Z1.9-2003 (R2018) |
Sampling Procedures and Tables for Inspection by Variables for Percent Nonconforming |
07/09/2014 |
General I (QS/ RM) |
5-88 |
Complete |
ISO |
2859-1 Second edition 1999-11-15 |
Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection [Including: Technical Corrigendum 1 (2001), Amendment 1 (2011)] |
01/14/2019 |
Dental/ ENT |
4-256 |
Complete |
ANSI ADA |
Standard No. 132-2015 |
Scanning Accuracy of Dental Chairside and Laboratory CAD/CAM Systems |
07/09/2014 |
Radiology |
12-194 |
Complete |
ANSI HPS |
N43.6-2007 (R2013) |
Sealed Radioactive Sources - Classification |
12/23/2019 |
General II (ES/ EMC) |
19-32 |
Complete |
IEC |
62133-1 Edition 1.0 2017-02 |
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 1: Nickel systems |
12/23/2019 |
General II (ES/ EMC) |
19-33 |
Complete |
IEC |
62133-2 Edition1.0 2017-02 |
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems |
12/23/2019 |
General II (ES/ EMC) |
19-13 |
Complete |
IEC |
62133 Edition 2.0 2012-12 |
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications [Including: Corrigendum 1 (2013)] |
06/07/2021 |
Software/ Informatics |
13-119 |
Complete |
ANSI ISA |
62443-4-1-2018 |
Security for industrial automation and control systems Part 4-1: Product security development life-cycle requirements. |
12/23/2019 |
General Plastic Surgery/ General Hospital |
6-437 |
Complete |
ISO |
23907-2 First edition 2019-11 |
Sharps injury protection - Requirements and test methods - Part 2: Reusable sharps containers. |
12/23/2019 |
General Plastic Surgery/ General Hospital |
6-426 |
Complete |
ISO |
23907-1 First edition 2019-01 |
Sharps injury protection - Requirements and test methods - Sharps containers |
01/30/2014 |
General Plastic Surgery/ General Hospital |
6-273 |
Complete |
ISO |
23908 First edition 2011-06-11 |
Sharps injury protection - Requirements and test methods - Sharps protection features for single-use hypodermic needles, introducers for catheters and needles used for blood sampling |
07/06/2020 |
General I (QS/ RM) |
5-128 |
Complete |
ISTA |
3E 2017 |
Similar Packaged-Products in Unitized Loads of Truckload Shipment |
12/18/2023 |
Cardiovascular |
3-190 |
Complete |
ISO |
PAS 7020 First edition 2023-05 |
Sizing parameters of surgical valve prostheses: Requirements regarding the application of ISO 5840-2 |
06/27/2016 |
General I (QS/ RM) |
5-108 |
Complete |
ISO |
80369-6 First Edition 2016-03-15 |
Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neuraxial applications. |
01/14/2019 |
General I (QS/ RM) |
5-121 |
Complete |
ISO |
80369-1 Second edition 2018-11 |
Small-bore connectors for liquids and gases in healthcare applications - Part 1: General requirements |
08/14/2015 |
General I (QS/ RM) |
5-97 |
Complete |
ISO |
80369-20 First edition 2015-05-15 |
Small-bore connectors for liquids and gases in healthcare applications - Part 20: Common test methods |
ANSI AAMI ISO |
80369-20:2015 |
Small-bore connectors for liquids and gases in healthcare applications - Part 20: Common test methods |
07/15/2019 |
General I (QS/ RM) |
5-123 |
Complete |
ISO |
80369-3 First Edition 2016-07-01 |
Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications [Including AMENDMENT 1 (2019)]. |
08/21/2017 |
General I (QS/ RM) |
5-107 |
Complete |
IEC |
80369-5: Edition 1.0 2016-03 |
Small-bore connectors for liquids and gases in healthcare applications - Part 5: Connectors for limb cuff inflation applications.[Including Corrigendum 1 (2017) and Corrigendum 2 (2021)] |
ANSI AAMI ISO |
80369-5:2016 |
Small-bore connectors for liquids and gases in healthcare applications - Part 5: Connectors for limb cuff inflation applications |
12/21/2020 |
General I (QS/ RM) |
5-133 |
Complete |
ISO |
80369-7 Second edition 2021-05 |
Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications |
12/20/2021 |
General Plastic Surgery/ General Hospital |
6-466 |
Complete |
USP-NF |
M76070_03_01 |
Sodium Chloride Injection |
12/20/2021 |
General Plastic Surgery/ General Hospital |
6-465 |
Complete |
USP-NF |
M76090_03_01 |
Sodium Chloride Irrigation |
07/06/2020 |
Software/ Informatics |
13-115 |
Complete |
ISO IEC IEEE |
29119-1 First edition 2013-09-01 |
Software and systems engineering - Software testing - Part 1: Concepts and definitions |
10/09/2023 |
Software/ Informatics |
13-129 |
Complete |
ISO IEC IEEE |
29119-1 Second edition 2022-01 |
Software and systems engineering - Software testing - Part 1: General concepts |
12/21/2020 |
Materials |
8-548 |
Complete |
ISO ASTM |
52915 Third edition 2020-03 |
Specification for additive manufacturing file format (AMF) Version 1.2 |
08/20/2012 |
Software/ Informatics |
13-31 |
Complete |
CLSI |
AUTO12-A |
Specimen Labels: Content and Location, Fonts, and Label Orientation; Approved Standard |
09/21/2016 |
General Plastic Surgery/ General Hospital |
6-380 |
Complete |
ISO |
9626 Second edition 2016-08-01 |
Stainless steel needle tubing for the manufacture of medical devices - Requirements and test methods |
09/09/2008 |
Software/ Informatics |
13-20 |
Complete |
CLSI |
LIS05-A |
Standand Specification for Transferring Clinical Observations Between Independent Computer Systems |
07/09/2014 |
Tissue Engineering |
15-40 |
Complete |
ASTM |
F2211-13 |
Standard Classification for Tissue Engineered Medical Products (TEMPs) |
07/09/2014 |
Anesthesiology |
1-101 |
Complete |
CGA |
C-9:2013 |
Standard Color Marking of Compressed Gas Containers for Medical Use |
12/21/2020 |
General Plastic Surgery/ General Hospital |
6-449 |
Partial |
ASTM |
F1169-19 |
Standard Consumer Safety Specification for Full-Size Baby Cribs |
01/14/2019 |
Materials |
8-489 |
Complete |
ASTM |
F3302-18 |
Standard for Additive Manufacturing - Finished Part Properties - Standard Specification for Titanium Alloys via Powder Bed Fusion |
01/14/2019 |
Materials |
8-488 |
Complete |
ASTM |
F3301-18a |
Standard for Additive Manufacturing - Post Processing Methods - Standard Specification for Thermal Post-Processing Metal Parts Made Via Powder Bed Fusion |
07/09/2014 |
Anesthesiology |
1-100 |
Complete |
CGA |
V-1:2013 |
Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connection |
12/19/2022 |
Software/ Informatics |
13-126 |
Complete |
ANSI AAMI UL |
2800-1-2:2022 |
Standard for Interoperable Item Development Life Cycle |
12/19/2022 |
Software/ Informatics |
13-127 |
Complete |
ANSI AAMI UL |
2800-1-3:2022 |
Standard for Interoperable Item Integration Life Cycle |
12/19/2022 |
Software/ Informatics |
13-121 |
Complete |
ANSI AAMI UL |
2800-1:2022 |
Standard for Medical Device Interoperability |
10/09/2023 |
Software/ Informatics |
13-131 |
Complete |
ANSI AAMI |
SW96:2023 |
Standard for medical device security - Security risk management for device manufacturers |
03/16/2012 |
Radiology |
12-177 |
Complete |
UL |
122-2007 (R2011) |
Standard for Photographic Equipment - Ed. 5.0 |
12/19/2022 |
Software/ Informatics |
13-125 |
Complete |
ANSI AAMI UL |
2800-1-1:2022 |
Standard for Risk Concerns for Interoperable Medical Products |
12/20/2021 |
General II (ES/ EMC) |
19-41 |
Complete |
ANSI UL |
61010-1 3rd Ed, dated May 12, 2012 with revision through July 19, 2019 |
Standard for Safety for Electrical Equipment For Measurement, Control and Laboratory Use; Part 1: General Requirements |
06/07/2018 |
Software/ Informatics |
13-104 |
Complete |
UL ANSI |
2900-2-1 First Edition 2017 |
Standard for Safety, Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems |
08/21/2017 |
Software/ Informatics |
13-96 |
Complete |
UL ANSI |
2900-1 First Edition 2017 |
Standard for Safety, Standard for Software Cybersecurity Network-Connectable Products, Part 1: General Requirements |
04/04/2016 |
General I (QS/ RM) |
5-98 |
Complete |
ANSI ESD |
S20.20-2014 |
Standard for the Development of an Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices) |
12/19/2022 |
General I (QS/ RM) |
5-141 |
Complete |
ASME |
V&V 20-2009 (R2021) |
Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer |
12/19/2022 |
General I (QS/ RM) |
5-140 |
Complete |
ASME |
V&V 10-2019 |
Standard for Verification and Validation in Computational Solid Mechanics |
06/07/2021 |
Cardiovascular |
3-168 |
Partial |
IEEE |
Std 1708-2014 |
Standard for Wearable, Cuffless Blood Pressure Measuring Devices [Including: Amendment 1 (2019)] |
12/19/2022 |
Software/ Informatics |
13-128 |
Complete |
IEEE UL |
Std 2621.2-2022 |
Standard for Wireless Diabetes Device Security: Information Security Requirements for Connected Diabetes Solutions |
02/20/2023 |
Sterility |
14-575 |
Complete |
ASTM |
F1980-21 |
Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices |
12/23/2016 |
Sterility |
14-497 |
Complete |
ASTM |
F1980-16 |
Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices |
12/23/2019 |
Cardiovascular |
3-162 |
Complete |
ASTM |
F3374-19 |
Standard Guide for Active Fixation Durability of Endovascular Prostheses |
06/07/2018 |
Materials |
8-463 |
Complete |
ISO ASTM |
52901 First edition 2017-08 |
Standard Guide for Additive Manufacturing - General Principles - Requirements for Purchased AM Parts |
09/17/2018 |
Sterility |
14-517 |
Complete |
ASTM |
F3293-18 |
Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices |
06/07/2018 |
Tissue Engineering |
15-53 |
Complete |
ASTM |
F3206-17 |
Standard Guide for Assessing Medical Device Cytocompatibility with Delivered Cellular Therapies |
07/06/2020 |
Tissue Engineering |
15-59 |
Complete |
ASTM |
F2450-18 |
Standard Guide for Assessing Microstructure of Polymeric Scaffolds for Use in Tissue-Engineered Medical Products |
07/06/2020 |
Materials |
8-532 |
Complete |
ASTM |
F3335-20 |
Standard Guide for Assessing the Removal of Additive Manufacturing Residues in Medical Devices Fabricated by Powder Bed Fusion |
08/21/2017 |
Materials |
8-455 |
Complete |
ASTM |
F2902-16 |
Standard Guide for Assessment of Absorbable Polymeric Implants |
09/17/2018 |
Orthopedic |
11-340 |
Complete |
ASTM |
F3018-17 |
Standard Guide for Assessment of Hard-on-Hard Articulation Total Hip Replacement and Hip Resurfacing Arthroplasty Devices |
07/06/2020 |
General Plastic Surgery/ General Hospital |
6-444 |
Complete |
ASTM |
D7103-19(2023) |
Standard Guide for Assessment of Medical Gloves |
04/04/2016 |
Tissue Engineering |
15-43 |
Complete |
ASTM |
F2791-15 |
Standard Guide for Assessment of Surface Texture of Non-Porous Biomaterials in Two Dimensions |
12/21/2020 |
Materials |
8-538 |
Complete |
ASTM |
F2759-19 |
Standard Guide for Assessment of the Ultra High Molecular Weight Polyethylene (UHMWPE) Used in Orthopedic and Spinal Devices |
07/06/2020 |
Sterility |
14-539 |
Complete |
ASTM |
F2475-20 |
Standard Guide for Biocompatibility Evaluation of Medical Device Packaging Materials |
01/14/2019 |
Cardiovascular |
3-66 |
Complete |
ASTM |
F2081-06 (Reapproved 2017) |
Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents |
06/07/2018 |
Tissue Engineering |
15-52 |
Complete |
ASTM |
F2064-17 |
Standard Guide for Characterization and Testing of Alginates as Starting Materials Intended for Use in Biomedical and Tissue Engineered Medical Product Applications |
07/06/2020 |
Tissue Engineering |
15-61 |
Complete |
ASTM |
F2150-19 |
Standard Guide for Characterization and Testing of Biomaterial Scaffolds Used in Regenerative Medicine and Tissue-Engineered Medical Products |
07/15/2019 |
Tissue Engineering |
15-58 |
Complete |
ASTM |
F2103-18 |
Standard Guide for Characterization and Testing of Chitosan Salts as Starting Materials Intended for Use in Biomedical and Tissue-Engineered Medical Product Applications |
06/07/2018 |
Tissue Engineering |
15-51 |
Complete |
ASTM |
F2347-15 |
Standard Guide for Characterization and Testing of Hyaluronan as Starting Materials Intended for Use in Biomedical and Tissue Engineered Medical Product Applications |
08/21/2017 |
Tissue Engineering |
15-49 |
Complete |
ASTM |
F2027-16 |
Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
12/23/2016 |
Orthopedic |
11-317 |
Complete |
ASTM |
F3129-16 |
Standard Guide for Characterization of Material Loss from Conical Taper Junctions in Total Joint Prostheses |
06/07/2021 |
Tissue Engineering |
15-67 |
Complete |
ASTM |
F2212-20 |
Standard Guide for Characterization of Type I Collagen as Starting Materials for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs) |
06/07/2021 |
Orthopedic |
11-380 |
Complete |
ASTM |
F2979-20 |
Standard Guide for Characterization of Wear from the Articulating Surfaces in Retrieved Metal-on-Metal and other Hard-on-Hard Hip Prostheses |
09/17/2018 |
Cardiovascular |
3-153 |
Complete |
ASTM |
F2743-11 |
Standard Guide for Coating Inspection and Acute Particulate Characterization of Coated Drug-Eluting Vascular Stent Systems |
09/09/2008 |
Software/ Informatics |
13-24 |
Complete |
CLSI |
LIS09-A |
Standard Guide for Coordination of Clinical Laboratory Services within the Electronic Health Record Environment and Networked Architectures |
12/21/2020 |
Sterility |
14-553 |
Complete |
ASTM |
F2097-20 |
Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products |
12/20/2021 |
Cardiovascular |
3-179 |
Complete |
ASTM |
F3172-15 (Reapproved 2021) |
Standard Guide for Design Verification Device Size and Sample Size Selection for Endovascular Devices |
12/23/2019 |
Sterility |
14-538 |
Complete |
ASTM |
F3357-19 |
Standard Guide for Designing Reusable Medical Devices for Cleanability |
09/09/2008 |
Software/ Informatics |
13-19 |
Complete |
CLSI |
LIS04-A |
Standard Guide for Documentation of Clinical Laboratory Computer Systems |
04/04/2016 |
Materials |
8-408 |
Complete |
ASTM |
F3122-14 |
Standard Guide for Evaluating Mechanical Properties of Metal Materials Made via Additive Manufacturing Processes |
12/19/2022 |
Orthopedic |
11-395 |
Complete |
ASTM |
F1814-22 |
Standard Guide for Evaluating Modular Hip and Knee Joint Components |
09/17/2018 |
Materials |
8-470 |
Complete |
ASTM |
F2102-17 |
Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants |
07/09/2014 |
Orthopedic |
11-276 |
Complete |
ASTM |
F1798-13 |
Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
12/20/2021 |
Materials |
8-572 |
Complete |
ASTM |
F2565-21 |
Standard Guide for Extensively Irradiation-Crosslinked Ultra-High Molecular Weight Polyethylene Fabricated Forms for Surgical Implant Applications |
09/17/2018 |
Cardiovascular |
3-154 |
Complete |
ASTM |
F3211-17 |
Standard Guide for Fatigue-to-Fracture (FtF) Methodology for Cardiovascular Medical Devices |